4.0 Article

Effect of non-thermal argon plasma on the shear strength of adhesive systems

期刊

POLIMEROS-CIENCIA E TECNOLOGIA
卷 32, 期 1, 页码 -

出版社

ASSOC BRASIL POLIMEROS
DOI: 10.1590/0104-1428.20220019

关键词

argon plasma; non-thermal plasma; dentin bonding agents; dentin; shear strength

向作者/读者索取更多资源

This study evaluated the influence of non-thermal argon plasma on dentin and found that the shear strength significantly increased when dentin was treated with plasma, regardless of the application time.
This study evaluated the influence of non-thermal argon plasma applied to dentin on the shear strength of two adhesive systems. Ninety tooth fragments were embedded in epoxy resin and distributed into experimental groups (n=15): G1 and G4 - adhesive systems applied according to the manufacturers' instructions; G2 and G5 - dentin treated with nonthermal argon plasma for 30 seconds before hybridization; G3 and G6 - dentin treated with non-thermal argon plasma for 30 seconds after hybridization. Cylinders were made with composite resin in the adhesive area, and the specimens were submitted to the shear strength test. Higher values were observed when applying the plasma treatment after hybridization (G1: 26.51 MPa, G2: 29.22 MPa, G3: 30.27 MPa, G4: 22.66 MPa, G5: 28.33 MPa, G6: 29.32 MPa). The treatment with non-thermal argon plasma significantly increased the shear strength values regardless of the application time.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据