4.3 Article

A High Precision and Fast Alignment Method Based on Binocular Vision

出版社

KOREAN SOC PRECISION ENG
DOI: 10.1007/s12541-022-00674-7

关键词

Visual alignment; Binocular vision; Camera calibration; Image processing

资金

  1. Youth Innovation Promotion Association, CAS [2020139]

向作者/读者索取更多资源

This study proposes a high precision and fast alignment method based on binocular vision, which allows for accurate alignment of the workpiece in one operation without the need for a standard calibration board. By using the proposed calibration and feature point detection methods, the position and pose of the workpiece are obtained, and alignment commands are calculated for precise alignment.
Alignment tasks for precision electronics manufacturing require high accuracy and low time consumption. However, in the current industrial environment, multiple servo alignment operations are often required to achieve the desired accuracy targets, which is time-consuming. In this paper, a high precision, fast alignment method based on binocular vision is proposed, which allows the accurate movement of the workpiece to the target position in only one alignment operation, without the need for a standard calibration board. Firstly, a calibration method of the telecentric lens camera is proposed based on an improved nonlinear damped least-squares method to establish the relationship between the image coordinate system and the local world coordinate system in the binocular vision system. Secondly, in order to transform the coordinates from the local world coordinate system to a unified coordinate system with the platform's rotation center as the origin, an angle constraint-based rotation center calibration method is proposed. Thirdly, a two-stage feature point detection method based on shape matching is proposed to detect the feature points of the workpiece. Based on these, the position and pose of the workpiece are obtained. Then the alignment commands are calculated based on the current and the target position and pose of the workpiece, enabling the accurate alignment to be accomplished in one operation. Finally, taking the mobile phone's cover glass alignment task as an example, a series of calibration and alignment experiments were carried out. The experiments and results show that the alignment errors are within +/- 0.020 mm and the time taken to calculate alignment commands is less than 20 ms, which demonstrates the effectiveness of the proposed method.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据