4.6 Article

Retention of sulfidated nZVI (S-nZVI) in porous media visualized by X-ray μ-CT - the relevance of pore space geometry

期刊

ENVIRONMENTAL SCIENCE-NANO
卷 9, 期 9, 页码 3439-3455

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d2en00224h

关键词

-

资金

  1. Metal-Aid Innovative Training Network (ITN) - European Commission's Marie Skowdowska Curie Actions program [675219]
  2. Villum Foundation 'Experiment' [36062]
  3. Danish Agency for Science, Technology, and Innovation
  4. Marie Curie Actions (MSCA) [675219] Funding Source: Marie Curie Actions (MSCA)

向作者/读者索取更多资源

This study describes an X-ray microcomputed tomography (μCT) approach for investigating the retention mechanisms of nanoparticles. Experimental results show that retention of sulfidated nanoscale zerovalent iron (S-nZVI) is determined by physical straining, with limited depth extension. Ripening deposition is also observed, increasing with decrease in injection velocity and/or increase in S-nZVI concentration. The local pore geometry and flow regime strongly influence S-nZVI attachment and retention, suggesting the need for pore space descriptors and velocity in predictive models.
Obtaining pore scale knowledge about retention mechanisms of nanoparticles (NP) is inherently difficult and can in turn restrict accurate forward prediction. Herein, an X-ray microcomputed tomography (mu-CT, 0.5 mu m pixel size) approach is described which is capable of resolving sulfidated nanoscale zerovalent iron (S-nZVI) retention at the pore scale, by using difference images of pre- and post-injection scans to account for local background variations around grains on a per pixel basis. The type of information that can be obtained from this approach including its limitations is discussed based on a first set of S-nZVI transport experiments performed in columns filled with irregular fine sand, where mu-CT images were obtained before and after S-nZVI injection at three positions along the column. A total of 5 column experiments were performed testing the effect of three different superficial injection velocities (5.8 x 10(-4) m s(-1), 2.9 x 10(-4) m s(-1) and 1.5 x 10(-4) m s(-1)) and three different S-nZVI concentrations (5.0 g L-1, 10 g L-1 and 20 g L-1) on S-nZVI retention behaviour, while the total injected S-nZVI mass was kept constant across experiments. The results clearly show that S-nZVI retention is determined by physical straining. Column depth and S-nZVI aggregate size dependency during straining appears to play a role, yet depth extension seems limited. Ripening deposition likely also occurred and increased with a decrease in injection velocity and/or increase in S-nZVI concentration. The local pore geometry and the flow regime strongly impacted S-nZVI attachment and retention behaviour, which suggests that pore space descriptors and velocity should be included in future predictive models. Together these results provide new perspectives for further studies of nZVI-based particle retention and transport in porous media.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据