期刊
IEEE JOURNAL OF EMERGING AND SELECTED TOPICS IN POWER ELECTRONICS
卷 4, 期 3, 页码 808-814出版社
IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/JESTPE.2016.2571302
关键词
Differential-mode (DM) filter; gallium nitride (GaN); interleaving; MHz; microcontroller (MCU); totem-pole power factor correction (PFC)
This paper presents a comparison between the performances of different interleaving control methods for gallium nitride devices-based MHz critical conduction mode (CRM) totem-pole power factor correction (PFC) circuit. Both closed-loop interleaving and open-loop interleaving are good for the 70-kHz CRM PFC; but for a MHz frequency CRM PFC with microcontroller (MCU) implementation, the open-loop interleaving outperforms the closed-loop interleaving with only a small and nonamplified phase error. After software optimization, the phase error of the open-loop interleaving is smaller than 3 degrees at 1 MHz, when the control is implemented by a 60-MHz low-cost MCU. Significant ripple cancellation effect and differential-mode (DM) filter size reduction are achieved with good interleaving. For a 1.2-kW MHz totem-pole PFC, the DM filter size is reduced to one quarter when compared with the counterpart of a 100-kHz PFC. Last but not least, the stability of the open-loop interleaving is also analyzed indicating that the MHz CRM totem-pole PFC with voltage-mode control, open-loop interleaving, and turn-on instant synchronization can maintain critical mode operation with better stability compared with the 70-kHz CRM PFC.
作者
我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。
推荐