4.5 Article

Removal of per- and polyfluoroalkyl substances from contaminated groundwater by granular activated carbon and anion exchange resins: a pilot-scale comparative assessment

期刊

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d2ew00080f

关键词

-

向作者/读者索取更多资源

This study evaluated and compared the adsorption of PFASs in contaminated groundwater using granular activated carbon (GAC) and anion exchange resins (AER). The results showed that AERs adsorbed 6-7 times more PFASs than GAC based on media mass or volume. However, when considering the same flowrate, AERs performed similarly to GAC for PFCAs and better for PFSAs. The study also assessed the operational costs of both treatment methods and found that AER and GAC could have similar costs if the ratio of AER to GAC unit media costs was around 3.5.
Granular activated carbon (GAC) and anion exchange resins (AER) are commonly used for the remediation of per- and polyfluoroalkyl substances (PFASs). This contribution reports on a continuous-flow pilot-scale system operated for similar to 1 year to evaluate and compare adsorption of 9 PFASs in contaminated groundwater by one GAC and three AERs operated at 10 and 2.5 min empty bed contact times, respectively, at the same column flowrates. Breakthrough of individual perfluorocarboxylic acids (PFCAs) and perfluorosulfonic acids (PFSAs) for GAC and PFCAs for AERs were influenced by compound chain length. However, breakthrough of PFSAs for all AERs occurred at the same time, possibly due to AER fouling by metals present in the source groundwater. Adsorption trends and capacity were similar amongst the three AERs evaluated. Dissolved organic carbon (DOC) was continuously removed by GAC and AERs and anionic species were not shown to be appreciably removed by AERs. Comparisons between GAC and AER were evaluated based on treatment efficacy and estimated operational costs. For comparison metrics influenced by media mass or volume including bed volumes treated, mass of PFAS adsorbed per media mass, and mass of media used per volume of water treated, AERs adsorbed 6-7 times more PFASs than GAC. However, based on volume of water treated where the columns were operated at the same flowrate, AERs performed similarly to GAC for PFCAs and better than GAC for PFSAs. Breakthrough of PFCAs will likely dictate media changeout due to the earlier breakthrough of PFCAs compared to PFSAs. GAC and AERs treated similar volumes of water prior to breakthrough of PFCAs suggesting that GAC and AER may be similarly effective PFAS treatment technologies. For AER and GAC O&M costs to be similar, the ratio of AER to GAC unit media costs was similar to 3.5.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据