4.4 Article

Comparing treatment of proximal phalangeal fractures with intramedullary screws versus plating

期刊

出版社

SPRINGER
DOI: 10.1007/s00402-022-04516-z

关键词

Phalangeal fracture; Proximal phalanx; Intramedullary screw osteosynthesis; Plate

资金

  1. University of Bern

向作者/读者索取更多资源

This study presents a modified approach to the fixation of proximal phalangeal fractures and compares outcomes with plate osteosynthesis. The results show that minimally invasive cannulated screw osteosynthesis has better treatment outcomes and shorter work disability duration.
Purpose Phalangeal fractures are the most common injuries in humans and account for approximately 10% of all fractures. With plate fixation, anatomic reduction is achievable in most cases, but extension lag is seen in up to 67%. Intramedullary headless screw offers treatment of unstable proximal phalangeal fractures using a minimally invasive procedure with very few complications. One of the major disadvantages of this technique is the transarticular screw position, damaging the articular surface and thus preventing very proximal fractures from being treated with a distally inserted screw. In this study, we present a modified approach to the fixation of the proximal phalangeal fractures and compare outcomes with plate osteosynthesis. Materials and methods Twenty-nine patients with 31 comparable fractures of the proximal phalanx were treated either with a plate (14) or with minimal invasive cannulated compression screw (17). Pain, strength, range of motion (ROM), work disability and QuickDASH score were assessed. Results TAM was significantly better in the screw group. The extension lag was worse in the plate group. Plate removal had to be performed in 13 of 14 the cases, while the screw had to be removed in only 3 cases. The average duration of work disability was 9.9 weeks in the plate group, compared to 5.6 weeks in the screw group. Conclusion Minimally invasive screw osteosynthesis not only has the advantage of significantly shorter work disabilities, but also shows remarkably improved postoperative range of motion. In contrast to plate osteosynthesis, removal of the screw is only necessary in exceptional cases. With the antegrade screws position, even difficult fractures close to the base can be treated without destroying any articular surface. In proximal phalanx fractures with both options of plate or single-screw osteosynthesis, we recommend minimal invasive cannulated screw osteosynthesis.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据