This study examined the fouling characteristics of reverse osmosis (RO) membranes taken from a potable reuse facility. The results revealed that the fouling varied among different stages and elements, with bioorganics dominating the fouling. Cleaning agents were found to be effective against bioorganics but not silicon fouling. The study highlights the importance of analyzing and evaluating the post-cleaning characteristics of RO membranes to optimize pretreatment and cleaning protocols.
We examined how colloidal, biological, organic, and inorganic fouling varied in 4-year-old reverse osmosis (RO) membranes taken from lead and lag ends of pressure vessels of each of the three stages from the world's largest potable reuse facility. Colorimetry, microscopy, spectroscopy, and microbial analysis revealed varying combined fouling extents in all cases. Bioorganics dominated all but the last element. In the first and second stages, non-siliceous multivalent inorganics accumulated more on lead elements, whereas silicon-based foulants prevailed in lag elements. The third-stage lag element suffered the heaviest inorganic and the lowest bioorganic fouling. Cleaning small swatches cut from each element with a mixture of sodium tripolyphosphate and sodium dodecylbenzenesulfonic acid fully recovered the permeability of only the lag element of the first stage, which had endured the lowest inorganic fouling. Partial permeability recovery of all of the other elements suggested that cleaning was only effective against bioorganics, and harsher cleaners and/or interstage treatment were needed to combat silicon fouling. Cleaning agents did not appear to penetrate and remove entrapped foulants, resulting in faster performance deterioration when the membranes resumed service post-cleaning. Results emphasize the importance of systematically autopsying elements from each stage and evaluating their post-cleaning characteristics to optimize RO pretreatment and cleaning protocols.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.2
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据