4.7 Article

Size-selective filtration of extracellular vesicles with a movable-layer device

期刊

LAB ON A CHIP
卷 22, 期 19, 页码 3699-3707

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d2lc00441k

关键词

-

资金

  1. National Research Foundation of Korea (NRF) - Korea government (MSIP) [NRF-2016R1A5A1010148, 2020R1A2B5B01002241]
  2. Korea Institute of Energy Technology Evaluation and Planning (KETEP)
  3. Ministry of Trade, Industry and Energy (MOTIE) [20174010201490]
  4. National Research Foundation of Korea [2020R1A2B5B01002241] Funding Source: Korea Institute of Science & Technology Information (KISTI), National Science & Technology Information Service (NTIS)

向作者/读者索取更多资源

This study introduces a microfluidic device that can isolate extracellular vesicles (EVs) with multiple size intervals in a simple and automated manner. By adjusting plunger speed, using a vertically movable plunger, and rotationally movable chip, high separation resolution and high-purity EVs were obtained. The device has potential applications in molecular analysis and EV-based biomarker discovery using various biofluids.
This paper presents a microfluidic device that can isolate extracellular vesicles (EVs) with multiple size intervals in a simple, effective, and automated manner. We accomplish this size-selective separation using a vertically movable plunger and a rotationally movable chip. The chip has open chambers with nanoporous filters that are sequentially connected by check valves. The plunger speed is adjusted to reduce chamber pressurization in order to prevent EV deformation, thereby achieving a high separation resolution. Herein, high-purity EVs with a purity ten times higher than that of ultracentrifugation were obtained by washing three times with a high EV recovery rate of 89%. For the analysis of device performance, we used polymer nanobeads, preformed liposomes, and canine blood plasma. To demonstrate the utility of the device, we applied size-selective isolation to EVs that were secreted by endothelial cells under shear flow. The results revealed that the cells secreted more EVs of larger size, the expression of CD63 protein was higher for EVs with a larger size, and a high amount of TSG101 protein was expressed under the condition of no shear flow. This device is envisioned to facilitate molecular analysis and EV-based biomarker discovery that use various biofluids, including blood plasma, urine, and cell culture supernatants. Our device automates size-selective EV filtration that requires laborious multiple washing and separation steps.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。