Radiometric calibration of a large-array commodity CMOS multispectral camera for UAV-borne remote sensing

出版社

ELSEVIER
DOI: 10.1016/j.jag.2022.102968

关键词

Radiometric calibration; Multispectral camera; Large-array commodity CMOS; Atmospheric correction; Unmanned aerial vehicle (UAV)

资金

  1. Major Program of the National Natural Science Foundation of China [42130106]
  2. Science and Technology Innovation Action Plan project of the Science and Technology Commission of Shanghai Municipality [20XD1403800, 19DZ2200800]

向作者/读者索取更多资源

This paper proposes an integrated indoor and outdoor radiometric calibration method, which corrects the vignetting effect and quantum efficiency using the lookup table (LUT) method and exponential nonlinear model respectively. Additionally, an empirical line method is presented to correct the atmospheric path radiance, improving the accuracy of reflectance calculation.
To meet the requirement of high-resolution and high-efficiency unmanned aerial vehicle (UAV)-borne multi-spectral remote sensing, using the miniaturized large-array commodity complementary metal-oxide semi-conductor (CMOS) camera is an effective solution. Given the characteristics of the new sensor and platform, almost no systematic and feasible radiometric calibration method has been specifically developed. In this paper, we proposed an indoor and outdoor integrated radiometric calibration method. To develop a systematic indoor calibration method, we explored the optimal methods for dark current offset, vignetting effect correction, and quantum efficiency calibration. According to the comparison results of three different methods, the lookup table (LUT) method was chosen to correct vignetting effect rather than nonlinear regression. Further, we proposed an exponential nonlinear model to replace the traditional linear model for quantum efficiency calibration, which improved the R-squares from around 0.92 to around 0.99. The outdoor calibration included atmospheric path radiance and reflectance correction. We proposed an empirical line method based on the dark target method to correct the atmospheric path radiance before the reflectance correction. Based on our method, the mean absolute percentage errors (MAPE) between the observed reflectance and the true reflectance were around 10%. More-over, the method can greatly improve the calculated reflectance accuracy of low reflectance targets. Our method can serve as a useful reference for the radiometric calibration of large-array commodity CMOS multispectral cameras. It can also contribute to the application of UAV-borne multispectral remote sensing.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据