Energy Optimisation of Propagation-Based Phase-Contrast Computed Tomography: A Quantitative Image Quality Assessment

期刊

出版社

SPIE-INT SOC OPTICAL ENGINEERING
DOI: 10.1117/12.2608596

关键词

Breast neoplasms; phase-contrast imaging; propagation-based phase-contrast tomography; breast imaging; quantitative image quality

向作者/读者索取更多资源

This study aims to determine the optimal x-ray energy for PB-CT images of breast mastectomy samples and investigate the correlation between objective physical measures of image quality and subjective human observer scores. The results suggest that 30-34 keV provides optimum image quality for breast PB-CT.
Purpose: This study aims at establishing the optimum x-ray energy for synchrotron acquired propagation-based computed tomography (PB-CT) images to obtain highest radiological image quality of breast mastectomy samples. It also examines the correlation between objective physical measures of image quality with subjective human observer scores to model factors impacting visual determinants of image quality. Approach: Thirty mastectomy samples were scanned at Australian Synchrotron's Imaging and Medical Beamline. Samples were scanned at energies of 26, 28, 30, 32, 34, and 60 keV at a standard dose of 4mGy. Objective physical measures of image quality were assessed using signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), SNR/resolution (SNR/res), CNR/resolution (CNR/res) and visibility. Additional calculations for each measure were performed against reference absorption-based computer tomography (AB-CT) images scanned at 32 keV and 4mGy. This included differences in SNR (dSNR), CNR (dCNR), SNR/res (dSNR/res), CNR/res (dCNR/res), and visibility (dVis). Physical measures of image quality were also compared with visual grading analysis data to determine a correlation between observer scores and objective metrics. Results: For dSNR, dCNR, dSNR/res, dCNR/res, and dVis, a statistically significant difference was found between the energy levels. The peak x-ray energy for dSNR and dSNR/res was 60 keV. For dCNR and dCNR/res 34 keV produced the highest measure compared to 28 keV for dVis. Visibility and CNR correlate to 56.8% of observer scores. Conclusion: The optimal x-ray energy differs for different objective measures of image quality with 30-34 keV providing optimum image quality for breast PB-CT. Visibility and CNR correlate highest to medical imaging expert scores.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据