4.7 Article

Flexural behaviour of CNT-filled glass/epoxy composites in an in-situ environment emphasizing temperature variation

期刊

COMPOSITES PART B-ENGINEERING
卷 83, 期 -, 页码 166-174

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.compositesb.2015.08.035

关键词

Polymer-matrix composites (PMCs); Mechanical properties; Environmental degradation; Fractography; Carbon nanotube

资金

  1. National Institute of Technology Rourkela [TEQIP 104-FSD]
  2. Indian Institute of Science Bangalore
  3. Defence Research and Development Organization (ADE) Bangalore
  4. Council of Scientific and Industrial Research New Delhi [22(0594)/12EMR II]

向作者/读者索取更多资源

The paucity of structural defects in carbon nanotube (CNT) with unrivalled mechanical properties has always posed an interest to material scientists for its potential incorporation in soft polymer resins to achieve superior mechanical stability. Present investigation focuses on the assessment of flexural behaviour of glass/epoxy (GE) and multiwalled carbon nanotubes (MWCNT) embedded glass/epoxy (0.3 wt. % of epoxy) (CNT-GE) composites at different in-service environmental temperatures. In-situ 3-point bend tests were performed on GE and CNT-GE composites at -80 degrees C, -40 degrees C, room temperature (20 degrees C), 70 degrees C and 110 degrees C temperatures at 1 mm/min crosshead speed. The results revealed that at 110 degrees C temperature, the flexural strength of GE and CNT-GE composites was significantly decreased by 67% and 81% respectively in comparison to their strength at -80 degrees C temperature. Similarly, 38% and 77% decrement in modulus was noted for GE and CNT-GE composites respectively. Dynamic mechanical thermal analysis (DMTA) was carried out in the temperature range of -100 degrees C to 200 degrees C to correlate the mechanical and thermo-mechanical response of both the material systems. Addition of 03 wt. % MWCNT in GE composite resulted in lowering of glass transition temperature (T-g) by 12 degrees C. Furthermore, to understand various possible deformation and failure mechanisms, the post failure analysis of the fractured specimens, tested at different temperatures, was carried out using scanning electron microscope (SEM). The critical parameters needed during designing composite structures were calculated and modelled using Weibull constitutive model. (C) 2015 Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据