4.5 Article

More advantages of trocar compared than steel needle in deep venipuncture catheterization

期刊

MEDICINE
卷 101, 期 46, 页码 -

出版社

LIPPINCOTT WILLIAMS & WILKINS
DOI: 10.1097/MD.0000000000031216

关键词

deep venipuncture catheterization; steel needle; trocar

向作者/读者索取更多资源

This study compared the clinical advantages of trocar and steel needle in deep venipuncture catheterization. The results showed that the trocar group had better puncture comfort, higher successful catheter insertion, shorter puncture time, lower incidence of thrombosis, catheter fever, bleeding, and infection compared to the steel needle group.
Background: Deep venipuncture catheterization is widely used in clinical anesthesia. However, it is worth thinking about how to improve the rate of successful catheter insertion, and relieve patients' discomfort. This paper aimed to compare the clinical advantages between trocar and steel needle. Methods: Total 503 adult patients were recruited and randomly assigned. The control group was punctured with steel needle, and the experimental group was punctured with trocar needle. Clinical and followed-up information was recorded. Pearson's chi-squared and spearman test were performed to analyze the correlation between intervention and relative parameters. Univariate logistic regression was performed to verify the odds ratio of trocar needle compared with steel needle. Results: Pearson's chi-square test and Spearman's correlation test showed a significant correlation between puncture success, puncture comfort, successful catheter insertion, puncture time, thrombosis, catheter fever, bleeding, infection and interventions (P < .05). Univariate logistic regression showed that there existed better puncture comfort (odds ratio [OR] = 6.548, 95% confidence interval [CI]: 4.320-9.925, P < .001), higher successful catheter insertion (OR = 6.060, 95% CI: 3.278-11.204, P < .001), shorter puncture time (OR = 0.147, 95% CI: 0.093-0.233, P < .001), lesser thrombosis (OR = 0.194, 95% CI: 0.121-0.312, P < .001), lesser catheter fever (OR = 0.263, 95% CI: 0.158-0.438, P < .001), lesser bleeding (OR = 0.082, 95% CI: 0.045-0.150, P < .001) and lesser infection (OR = 0.340, 95% CI: 0.202-0.571, P < .001) in trocar group compared with steel needle group. Conclusion: Trocar application in deep venipuncture catheterization can improve successful catheter insertion, relieve pain and discomfort of patients, reduce incidence of complications, and provide better security for patients.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据