4.5 Article

Ultrasound-assessed lung aeration correlates with respiratory system compliance in adults and neonates with acute hypoxemic restrictive respiratory failure: an observational prospective study

期刊

RESPIRATORY RESEARCH
卷 23, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12931-022-02294-1

关键词

Acute respiratory distress syndrome; Lung mechanics; Lung ultrasound; Neonates

向作者/读者索取更多资源

There is a significant inverse correlation between lung ultrasound scores (LUS) and compliance of the respiratory system (Crs) in patients with acute hypoxemic restrictive respiratory failure, regardless of age. A restrictive respiratory failure has the same ultrasound appearance and mechanical characteristics in adults and neonates.
Background: Lung ultrasound allows lung aeration to be assessed through dedicated lung ultrasound scores (LUS). Despite LUS have been validated using several techniques, scanty data exist about the relationships between LUS and compliance of the respiratory system (Crs) in restrictive respiratory failure. Aim of this study was to investigate the relationship between LUS and Crs in neonates and adults affected by acute hypoxemic restrictive respiratory failure, as well as the effect of patients' age on this relationship. Methods: Observational, cross-sectional, international, patho-physiology, bi-center study recruiting invasively ventilated, adults and neonates with acute respiratory distress syndrome (ARDS), neonatal ARDS (NARDS) or respiratory distress syndrome (RDS) due to primary surfactant deficiency. Subjects without lung disease (NLD) and ventilated for extra-pulmonary conditions were recruited as controls. LUS, Crs and resistances (Rrs) of the respiratory system were measured within 1 h from each other. Results: Forty adults and fifty-six neonates were recruited. LUS was higher in ARDS, NARDS and RDS and lower in control subjects (overall p < 0.001), while Crs was lower in ARDS, NARDS and RDS and higher in control subjects (overall p < 0.001), without differences between adults and neonates. LUS and Crs were correlated in adults [r = - 0.86 (95% CI - 0.93; - 0.76), p < 0.001] and neonates [r = - 0.76 (95% CI - 0.85; - 0.62), p < 0.001]. Correlations remained significant among subgroups with different causes of respiratory failure; LUS and Rrs were not correlated. Multivariate analyses confirmed the association between LUS and Crs both in adults [B = - 2.8 (95% CI - 4.9; - 0.6), p = 0.012] and neonates [B = - 0.045 (95% CI - 0.07; - 0.02), p = 0.001]. Conclusions: Lung aeration and compliance of the respiratory system are significantly and inversely correlated irrespective of patients' age. A restrictive respiratory failure has the same ultrasound appearance and mechanical characteristics in adults and neonates.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据