4.6 Article

DC-Link Electrolytic Capacitors Monitoring Techniques Based on Advanced Learning Intelligence Techniques for Three-Phase Inverters

期刊

MACHINES
卷 10, 期 12, 页码 -

出版社

MDPI
DOI: 10.3390/machines10121174

关键词

capacitor monitoring; electrolytic capacitors; advanced learning intelligence

资金

  1. National Research Foundation of Korea (NRF) - Korea government (MSIT)
  2. Korea Electric Power Corporation
  3. [2020R1A2C1013413]
  4. [R21XA01-3]

向作者/读者索取更多资源

The reliability of electronic converters in industrialized areas is crucial, with capacitors being a critical component. This study proposes an estimation scheme using source current to assess capacitor health status and employs various advanced techniques to achieve this.
The reliability of the electronic converter is a vital concern in an industrialized area. Capacitors are critical in electronic converters and are more likely to fail than other electronic gears. Due to aging, the capacitor progressively loses its original quality and capacitance, and the equivalent series resistance escalates. Hence, condition monitoring is a fundamental procedure for evaluating capacitor health that affords prognostic repairs to guarantee stability in power networks. The ESR and capacitance of the capacitor are commonly employed to estimate the condition grade. This study proposes an estimation scheme that utilizes the source current to assess the health condition of an aluminum capacitor. Several advanced intelligence techniques are adopted to estimate the parameters of an AEC in a three-phase inverter system. First, different signals used as inputs, such as input power, capacitor current, voltage, and power, output current, voltage, and power, are analyzed using fast Fourier transform and discrete wavelet transform analysis. Then, various indexes of the analyzed signals, such as RMS, average, median, and variance, are used as the inputs in learning models to monitor the AEC's parameters. In addition, various input signals are combined to obtain the best combinations for capacitor monitoring. The estimated results prove that utilizing the source current combined with selected indexes improves the monitoring accuracy of the AEC's health status.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据