Electromagnetic navigation bronchoscopy-guided radiofrequency identification marking in wedge resection for fluoroscopically invisible small lung lesions

期刊

出版社

OXFORD UNIV PRESS INC
DOI: 10.1093/ejcts/ezad006

关键词

Wedge resection; Microchip; Small lung lesion; Margin; Depth

向作者/读者索取更多资源

This study developed a wireless localization technique for fluoroscopically invisible small lung lesions and compared two marking approaches with or without cone-beam computed tomography (CBCT). The results showed that electromagnetic navigation bronchoscopy-guided radiofrequency identification marking provided a high tumor resection rate with sufficient surgical margins. The use of CBCT for marking resulted in a shorter distance from the marker to the lesion.
OBJECTIVES We developed a novel wireless localization technique after electromagnetic navigation bronchoscopy-guided radiofrequency identification marker placement for fluoroscopically invisible small lung lesions. We conducted an observational study to investigate the feasibility of this technique and retrospectively compared 2 marking approaches with or without cone-beam computed tomography (CBCT).METHODS Consecutive patients from January 2021 to March 2022 in our institution were enrolled. Markers were placed central to the lesions either in a bronchoscopic suite under intravenous anaesthesia or a hybrid operation theatre with CBCT under general anaesthesia. The efficacy of the 2 marking methods was compared using an inverse probability of treatment weighting adjusted analysis.RESULTS Totally 80 markers were placed (45 under CBCT and 35 under fluoroscopy) for 74 patients with 80 lesions [mean size: 6.9 mm (interquartile range: 5.1-8.4) at a median depth from the pleura of 14.0 mm (interquartile range: 8.5-19.5)]. The median distance from marker to lesion was 9.1 mm, with a pleural depth of 15.5 mm. The tumour resection rate was 97.5% (78/80) with the median surgical margin of 10.0 mm (interquartile range: 8.0-11.0). Although the bronchoscopy time was longer using CBCT because of the need for 2.8 scans per lesion, the distance from the marker to the lesion was shorter for marking using CBCT than marking using fluoroscopy (adjusted difference: -4.56, 95% confidence interval: -6.51 to -2.61, P < 0.001).CONCLUSIONS Electromagnetic navigation bronchoscopy-guided radiofrequency identification marking provided a high tumour resection rate with sufficient surgical margins.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据