This study evaluated the flow-diversion characteristics of a novel primarily bioresorbable flow-diverting stent through experiments and animal models. The results demonstrated that the stent has flow-diversion characteristics comparable to commercially available metal stents.
OBJECTIVE Flow-diverting stents with a resorbable component have significant theoretical benefits over full metal stents, although currently there are none in clinical use. In this study, the authors sought to determine the immediate flow-diversion characteristics of a novel primarily bioresorbable flow-diverting stent.METHODS Bioresorbable stents were deployed into glass tube models to determine porosity and pore density. In vitro flow diversion behavior was evaluated using high frame rate angiography under pulsatile flow conditions in a patient -specific silicone aneurysm model treated with the resorbable stent as well as the Surpass Evolve stent. In vivo flow diversion was characterized by deployment into 20 rabbit saccular aneurysm models, and grading was based on the O'Kelly-Marotta scale and the 4F-flow diversion predictive score.RESULTS Porosities and pore densities of the bioresorbable stent were in the flow-diverting range for all target vessel diameters. Quantified results of immediate angiography after placement of the bioresorbable stent into a silicone aneu- rysm model demonstrated greater flow diversion compared to the Evolve stent. Bioresorbable stent placement in sac- cular aneurysm models resulted in an immediate O'Kelly-Marotta grade of A3 or better and a 4F-flow diversion predictive score of 4 or better in all cases.CONCLUSIONS The bioresorbable stent has immediate flow-diversion characteristics that are comparable to commer- cially available metal stents. Longer-term studies are underway to determine the ability of the resorbable fibers to act as a neointimal scaffold and result in long-term aneurysm occlusion.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据