4.0 Article

Analysis of surface characteristics of (Y, Nb)- TZP after finishing and polishing

期刊

JOURNAL OF ADVANCED PROSTHODONTICS
卷 14, 期 6, 页码 335-345

出版社

KOREAN ACAD PROSTHODONTICS
DOI: 10.4047/jap.2022.14.6.335

关键词

Fully sintered zirconia; Partially sintered zirconia; CAD-CAM restoration; Surface roughness; Phase transformation

资金

  1. Korea Medical Device Development Fund grant provided by the Korean Government (Ministry of Science and ICT, Ministry of Trade, Industry and Energy, Ministry of Health Welfare)
  2. Ministry of Food and Drug Safety [KMDF_PR_20200901_0002]

向作者/读者索取更多资源

This study evaluated the surface characteristics of a clinically fabricated (Y, Nb)-TZP zirconia full veneer crown. The results showed that grinding and polishing significantly reduced surface roughness and reduced grain exposure. The conventional zirconia polishing sequence can achieve a clinically acceptable level of surface finishing.
PURPOSE. This in vitro study aimed to evaluate the surface characteristics of a full veneer crown fabricated chairside (CS) from a (Y, Nb)-TZP zirconia block in response to conventional zirconia grinding and polishing. MATERIALS AND METHODS. Zirconia crowns (n = 40) were first prepared and divided into two groups of materials: Labside (LS) and CS, after which each specimen went through a five-step grinding and polishing procedure. Following each surface treatment, surface characteristics were analyzed using confocal laser microscopy (CLSM), average surface roughness (Ra) values were processed from the profile data through Gaussian filtering, and X-ray diffraction pattern analysis was performed to evaluate the monoclinic (M) phase content. Then, a representative specimen was selected for field-emission scanning electron microscopy (FE-SEM), followed by a final analysis of the roughness and X-ray diffraction of the specimens using the independent t-test and repeated measures analysis of variance (RM-ANOVA). RESULTS. In every group, polishing significantly reduced the Ra values (P < .001). There was no significant difference in Ra between the polished state CS and LS. Furthermore, CLSM and FE-SEM investigations revealed that even though grain exposure was visible in CS specimens throughout the as-delivered and ground states, the exposure was reduced after polishing. Moreover, while no phase transformation was visible in the LS, phase transformation was visible in CS after every surface treatment, with the M phase content of the CS group showing a significant reduction after polishing (P < .001). CONCLUSION. Within the limits of this study, clinically acceptable level of surface finishing of (Y, Nb)-TZP can be achieved after conventional zirconia polishing sequence. [J Adv Prosthodont 2022;14:335-45]

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.0
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据