Can the Use of Continuous Glucose Monitoring Improve Glycemic Control in Patients with Type 1 and 2 Diabetes Receiving Dialysis?

期刊

NEPHRON
卷 147, 期 2, 页码 91-96

出版社

KARGER
DOI: 10.1159/000525676

关键词

Diabetes; Continuous glucose monitoring; Hemodialysis; Peritoneal dialysis; Time in range

向作者/读者索取更多资源

CGM provides more detailed measurements of mean sensor glucose, glucose variability, and time in ranges, which can overcome the limitations of HbA1c in dialysis patients. It has the potential to improve glycemic control and detect hypoglycemia. However, the long-term use of CGM in the dialysis population has not been evaluated and practical burden and cost may be a limitation.
Background: Hemoglobin A1c (HbA1c) is an unreliable glycemic marker in the dialysis population, and alternative methods of glycemic monitoring should be considered. Continuous glucose monitoring (CGM) measures interstitial glucose, an indirect measure of plasma glucose, and allows for estimating mean sensor glucose, glucose variability, and time in ranges. Thus, CGM provides a more nuanced picture of glycemic variables than HbA1c, which only informs about average glucose and not variation in glucose or hypoglycemia. Summary: In non-dialysis patients with type 1 and type 2 diabetes, CGM metrics are increasingly used to estimate glycemic control and are associated with improvements in glucose levels. Although a clear link has not yet been established between some CGM variables and the development of late diabetic complications, CGM use could be an important step forward in improving glycemic control in patients receiving dialysis. The ability to detect and prevent hypoglycemia while optimizing glucose levels could be particularly valuable. However, long-term CGM use has not been evaluated in the dialysis population, and the practical burden and cost associated with CGM use may be a limitation. We discuss the strengths and limitations of using CGM in the dialysis population with type 1 and type 2 diabetes. Key Messages:CGM circumvents the pitfalls of HbA1c in dialysis patients and provides detailed measures of the mean sensor glucose, glucose variability, and time in ranges. Guidelines recommend a minimum of 50% time spent in the target range (3.9-10.0 mmol/L) and less than 1% below range (<3.9 mmol/L) for patients receiving dialysis but remain to be evaluated in the dialysis population. CGM can be a valuable tool in reducing overall glucose levels and variations while detecting hypoglycemia, but the practical burden of CGM use and cost may be a limitation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.1
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据