4.7 Article

Improved image quality and dose reduction in abdominal CT with deep-learning reconstruction algorithm: a phantom study

期刊

EUROPEAN RADIOLOGY
卷 33, 期 1, 页码 699-710

出版社

SPRINGER
DOI: 10.1007/s00330-022-09003-y

关键词

Artificial intelligence; Deep learning; Multidetector computed tomography; Image enhancement; Image processing; computer-assisted

向作者/读者索取更多资源

This study assessed the impact of a new AI reconstruction algorithm (AI-DLR) on image quality in abdominal CT. The results showed that using AI-DLR improved image quality, detectability of lesions, and spatial resolution. The Smooth level was found to be the best compromise between the lowest dose level and adequate image quality.
Objectives To assess the impact of a new artificial intelligence deep-learning reconstruction (Precise Image; AI-DLR) algorithm on image quality against a hybrid iterative reconstruction (IR) algorithm in abdominal CT for different clinical indications. Methods Acquisitions on phantoms were performed at 5 dose levels (CTDIvol: 13/11/9/6/1.8 mGy). Raw data were reconstructed using level 4 of iDose(4) (i4) and 3 levels of AI-DLR (Smoother/Smooth/Standard). Noise power spectrum (NPS), task-based transfer function (TTF) and detectability index (d ') were computed: d ' modelled detection of a liver metastasis (LM) and hepatocellular carcinoma at portal (HCCp) and arterial (HCCa) phases. Image quality was subjectively assessed on an anthropomorphic phantom by 2 radiologists. Results From Standard to Smoother levels, noise magnitude and average NPS spatial frequency decreased and the detectability (d ') of all simulated lesions increased. For both inserts, TTF values were similar for all three AI-DLR levels from 13 to 6 mGy but decreased from Standard to Smoother levels at 1.8 mGy. Compared to the i4 used in clinical practice, d ' values were higher using the Smoother and Smooth levels and close for the Standard level. For all dose levels, except at 1.8 mGy, radiologists considered images satisfactory for clinical use for the 3 levels of AI-DLR, but rated images too smooth using the Smoother level. Conclusion Use of the Smooth and Smoother levels of AI-DLR reduces the image noise and improves the detectability of lesions and spatial resolution for standard and low-dose levels. Using the Smooth level is apparently the best compromise between the lowest dose level and adequate image quality.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据