4.4 Review

Efficacy of high-intensity focused ultrasound combined with LNG-IUS for adenomyosis: a systematic review and meta-analysis

期刊

ARCHIVES OF GYNECOLOGY AND OBSTETRICS
卷 308, 期 2, 页码 351-362

出版社

SPRINGER HEIDELBERG
DOI: 10.1007/s00404-022-06720-z

关键词

HIFU; LNG-IUS; Adenomyosis; Meta-analysis

向作者/读者索取更多资源

The combination of HIFU and LNG-IUS for the treatment of adenomyosis has shown advantages in alleviating symptoms and reducing the volumes of the uterine and adenomyotic lesions.
Objective To evaluate the efficacy and safety of high-intensity focused ultrasound (HIFU) combined with the levonorgestrel intrauterine system (LNG-IUS) for adenomyosis. Methods We searched PubMed, Embase, Cochrane Library, Web of Science, CNKI, SinoMed, Wanfang, and VIP databases from their inception to Nov 20, 2021 for relevant articles that compared HIFU combined with LNG-IUS vs. HIFU alone in patients with adenomyosis. RevMan5.4 software was used for the data analysis. The primary outcome was changes in volume of the uterine. Secondary outcomes included visual analog scale (VAS) scores for dysmenorrhea, serum CA125 level, recurrence rate, changes in volume of the adenomyotic lesion, menstrual volume scores, and adverse reactions. Data synthesis was conducted using a random-effects model with significant heterogeneity (I-2 > 50%), and using a fixed-effects model otherwise. This study is registered on the PROSPERO platform (CRD42021295214). Results The final analysis included 13 studies, with a total of 1861 patients. Results of analysis revealed that there was no significant difference in uterine volume reduction between the HIFU control group and the HIFU/LNG-IUS group at 3 months after procedure (MD:30.63). Compared with the HIFU control group, the HIFU/LNG-IUS group had more pronounced reduction in uterine volume at 6 (MD:29.04) and 12 months (MD:22.10) after procedure. The HIFU/LNG-IUS group has lower VAS scores for dysmenorrhea than the HIFU control group at 3 (MD:1.68), 6 (MD:1.69), and 12 months (MD:1.30) after procedure. Serum CA125 level in the HIFU/LNG-IUS group decreased more significantly than the HIFU control group at 6 (MD:18.34) and 12 months (MD:18.49) after procedure. The recurrence rate in the HIFU/LNG-IUS group was lower than that in the HIFU control group (RR:0.20). Conclusions Compared to HIFU control group, HIFU/LNG-IUS group for the management of adenomyosis had more advantages in alleviating symptoms and decreasing the volumes of the uterine and adenomyotic lesions. However, since the number of the included studies was too small and some of them were not RCT, this conclusion needs to be referenced with caution.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据