4.7 Article

Experimental investigation of the heat transport and pressure drop in open-cell polyurethane foams

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.ijheatmasstransfer.2023.124709

关键词

Polyurethane foam; Open-cell foam; Heat transfer; Pressure drop

向作者/读者索取更多资源

Foam-like materials with large specific surface area and complex structure promote flow turbulence and are useful for heat transfer. This study experimentally investigated the hydraulic and heat transfer characteristics of polyurethane foam inserts in a rectangular channel, showing that although the heat transfer intensity of PUF samples is lower than that of metal foams, a significant heat transfer enhancement up to 7 times can still be achieved compared to an empty channel.
Foam-like materials have a large specific surface area and complex structure that promotes flow turbulence, which makes them useful for heat transfer. In the literature, heat transfer in metal foams (MF) with high thermal conductivity is mainly considered. In the present paper, an experimental study of the hydraulic and heat transfer characteristics of a rectangular channel filled with polyurethane foam (PUF) inserts with a thermal conductivity of 0.2 W center dot m- 1 center dot K-1 in the air flow was carried out. The open-cell PUF samples had 20 and 80 pores per inch (PPI), 0.97 and 0.98 porosity, 269 mu m and 60 mu m fiber diameter, respectively. The Reynolds number, based on the fiber diameter ranged from 0.04 to 50. From the results of hydraulic tests, friction coefficients were determined based on the fiber diameter and permeability. The Forchheimer coefficient was 0.198 and 0.318 for 20 and 80 PPI samples, respectively. The permeability was 1.889 10-7 center dot m2 and 7.535 10-9 center dot m2 for 20 and 80 PPI samples, respectively. The Nusselt number for both tested PUF samples was correlated with the Reynolds number based on the fiber diameter in a power law with the Reynolds number exponent and constant equal to 0.61 and 0.037 respectively. The intensity of heat transfer in the PUF samples was 7-12 times lower than that in MF. However, a significant heat transfer enhancement is still possible compared to the empty channel up to 7 times. The heat transfer performance of PUF was higher compared to the empty channel, but the thermal performance factor was lower than one. Nevertheless, in practical situations where the mass or cost of the heat exchanger is preferable, PUF can be considered as a heat transfer intensifier.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据