4.7 Article

Innovative concept of splitting water flow rate of cross flow heat exchangers as a solution for reduction of non-uniformity effect - Thermal modelling and feasibility analysis

期刊

APPLIED THERMAL ENGINEERING
卷 236, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.applthermaleng.2023.121483

关键词

Split concept; Cross-flow; HXs; Thermal modeling; Feasibility study

向作者/读者索取更多资源

This research splits the water flow rate of water-air cross-flow heat exchangers into smaller flow rates, leading to improved thermal performance. By dividing the water flow into multiple smaller passages, each associated with smaller heat exchangers, and sequentially combining the smaller heat exchangers with the air flow, the thermal performance can be increased globally.
The water flow rate of water-air cross-flow Heat Exchangers (HXs) is split into various smaller flow rates in this research work, which circulates into several smaller HXs that are put together. In fact, as the non-uniformities in the airflow velocity distributions increase, the thermal performance declines. These non-uniformities, especially in automotive applications, are represented by velocity magnitudes on a part of the HX front area and zero velocities on the remaining part. The innovative idea and the originality of the present study consists on dividing the water flow rates into various passageways as they reach a water-flow HX, where each passage is associated with several smaller HXs. In relation to the air flow, the smaller HXs are sequentially combined. The advantage of such splitting leads to keeping parts of the area of the initial HX from being subjected to low convection heat transfer with zero or negligible velocities and subsequently allows for an increase in the thermal performance globally. Moreover, the dividing idea enables faster but hotter airflow to be applied to each of the individual HXs. Computations for double-split HX utilizing a developed computational code are used to demonstrate the viability of this design. A traditional cross-flow water-air HX's thermal performance can be improved by up to 26.2 % using the novel idea, it has been demonstrated.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据