4.5 Article

Novel antibiotic irrigation device versus standard O-ring wound retractor in the prevention of surgical site infection following colorectal resection

期刊

出版社

SPRINGER
DOI: 10.1007/s00384-023-04542-2

关键词

Wound retractor; O-ring; Antibiotic irrigation; Surgical site infection; Colorectal resection

向作者/读者索取更多资源

The study aimed to compare the effectiveness of a novel antibiotic irrigation device and the standard O-ring wound retractor in preventing surgical site infections after colorectal resections. The results showed that the use of the novel device was associated with significantly lower SSI rates compared to the O-ring retractor, indicating that the novel device is more effective in preventing SSIs.
Purpose We sought to compare the effectiveness of a novel antibiotic irrigation device to the standard O-ring wound retractor in preventing surgical site infections (SSIs) following colorectal resections.Methods This single-arm clinical trial included patients undergoing colorectal resections utilizing the novel device. A retrospective cohort of patients undergoing the same procedures with the O-ring retractor was selected as the control group. The primary outcome assessed was SSI. Secondary outcomes assessed were overall complications, hospital length of stay (LOS), and 30-day readmission. A univariable and multivariable logistic regression model was built to evaluate the association between SSI as the outcome variable and the use of the novel device as the main independent variable. The model was adjusted for any confounding variables.Results Eighty-six novel device cases and 170 O-ring retractor cases were enrolled. There were no significant differences between the two groups in terms of demographics and preoperative comorbidities. Cases with the novel device had fewer Pfannenstiel incisions (1.2% vs. 14.6%, p < 0.001). There were no other significant differences in intraoperative variables. SSI rates were significantly lower in the novel device group (1.2% vs. 9.1%, p = 0.014). There were no other significant differences in postoperative complications. Multivariable logistic regression with backward elimination showed that the use of the novel device was significantly more effective against SSI by 92.5% compared to the use of the O-ring retractor.Conclusion The novel device may contribute to lower SSI rates compared to the O-ring retractor following colorectal resection.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据