4.5 Article

Experimental and numerical study of an innovative twined tube HX design

期刊

ANNALS OF NUCLEAR ENERGY
卷 195, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.anucene.2023.110185

关键词

Twined tube heat exchanger; CFD simulation; Thermal -hydraulic performance; Conjugate heat transfer; Performance factor

向作者/读者索取更多资源

An innovative twined tube heat exchanger design for advanced nuclear reactors is proposed, which is simple, robust, and efficient. Thermal-hydraulic investigations are performed through experiments and numerical simulations, showing that the performance factor of the twined tube heat exchanger is higher than that of straight tube heat exchanger, with a maximum enhancement of 60%. The proposed design is also easier to fabricate and maintain than helical coil heat exchangers.
An innovative twined tube heat exchanger (HX) design is proposed, which is simple, robust, and efficient for use in advanced nuclear reactors. The heat exchanger is designed with two tubes twined around each other. Multiple modules can be assembled within a shell to meet the necessary heat load. Thermal-hydraulic investigations of the novel design are performed through experiments and numerical simulation. The experimental investigations of the twined tube HX are carried out on a laboratory-scale thermal-hydraulic rig commissioned at the Pakistan Institute of Engineering & Applied Sciences (PIEAS). The primary loop contains water at a high temperature and a pressure of 4.0 bar pressure, while the secondary loop operates at atmospheric pressure. Single-phase forced convection heat transfer characteristics of the twined tube HX are investigated experimentally. Pressure drop is measured for mass fluxes ranging from 350 kg/m2s to 1376 kg/m2s. A correlation for the estimation of friction factor is developed based on the experimental studies. Heat transfer measurements are carried out for mass fluxes ranging from 244 kg/m2s to 419 kg/m2s. Based on these experiments, the Nusselt number is evaluated for the mass flux range mentioned above. The numerical simulations of a twined tube HX are performed on a full-scale STAR-CCM + model. The model is validated against the experimental results. The performance factor of the twined tube HX is higher than that of straight tube HX, with a maximum performance enhancement of 60%. The thermal-hydraulic performance of the twined tube HX is comparable with helical coil HX designs. However, the proposed HX design is easier to fabricate and maintain than the helical coiled HX. Overall, the study provides valuable insights into the thermal-hydraulic performance of the twined tube HX, which could be useful in the design of compact and efficient heat exchangers for small modular reactors.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据