4.5 Review

Performance of EUS-FNA and EUS-B-FNA for the diagnosis of left adrenal glands metastases in patients with lung cancer: A systematic review and meta-analysis

期刊

LUNG CANCER
卷 186, 期 -, 页码 -

出版社

ELSEVIER IRELAND LTD
DOI: 10.1016/j.lungcan.2023.107391

关键词

Lung cancer; Staging; Endosonography; Systematic review; Diagnostic accuracy

向作者/读者索取更多资源

This study evaluated the diagnostic performance of EUS and EUS-B in diagnosing left adrenal gland metastasis in lung cancer patients. The results showed that both procedures have good performance and are safe for analyzing the left adrenal gland. However, further high-quality studies are needed to confirm these findings.
Objectives: For diagnosing left adrenal gland metastasis in lung cancer, clinical guidelines recommend to perform EUS, but EUS-B (EUS using an EBUS-scope) is increasingly being used. We evaluated the diagnostic performance of both procedures.Materials and Methods: We did a systematic review (PROSPERO, CRD42023416205) and searched MEDLINE and EMBASE on 04-July-2023 for studies evaluating EUS and/or EUS-B in diagnosing left adrenal gland metastases in adults with (suspected) lung cancer. Outcomes were: (1) ability to visualize the left adrenal gland, (2) ability to sample (in those with successful visualization and in whom sampling was attempted), (3) ability to obtain adequate material (in those with successful sampling), (4) malignancy detection rate (in those with successful sampling), and (5) remaining risk of malignancy (in those with a negative EUS(-B)-FNA and undergoing a reference standard). We performed random-effects meta-analyses.Results: We included 19 studies (EUS: n = 11, EUS-B: n = 6, both: n = 2), covering 1712 patients. All studies had high (n = 18) or unclear (n = 1) risk of bias (QUADAS-2). Average ability to visualize the left adrenal gland was 0.94 (95 %CI 0.82-0.98; n = 7 studies). Average ability to sample was 1.00 (95 %CI 0.99-1.00; n = 9). Average ability to obtain adequate material was 0.96 (95 %CI 0.93-0.98; n = 18). Average malignancy detection rate was 0.42 (95 %CI 0.34-0.49; n = 18). Remaining risk of malignancy was 0.07 (95 %CI 0.04-0.12; n = 8). Ability to visualize was slightly higher for EUS (0.99; 95 %CI 0.90-1.00) than EUS-B (0.84; 95 %CI 0.70-0.92; p = 0.025), but the other performance characteristics were similar. No major complications were reported.Conclusion: Both EUS and EUS-B have good performance and are safe for left adrenal gland analysis in patients with lung cancer, but the number of high-quality studies is limited and further well-constructed prospective studies are needed.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据