4.5 Article

Development and characterisation of highly specific monoclonal antibody-based immunoassays for the detection and quantification of genistein-7-O-[α-rhamnopyranosyl-(1→6)]-β-glucopyranoside in Derris scandens (Roxb.) Benth.

期刊

PHYTOCHEMICAL ANALYSIS
卷 -, 期 -, 页码 -

出版社

WILEY
DOI: 10.1002/pca.3305

关键词

Derris scandens; ELISA; lateral-flow immunoassay; Mannich reaction; monoclonal antibody

向作者/读者索取更多资源

In this study, immunoassays utilizing specific anti-GTG monoclonal antibodies were successfully developed, including a lateral-flow immunoassay for rapid GTG detection and an icELISA for GTG quantification. The results showed that these methods exhibited high specificity and accuracy.
Introduction: The stem of the plant species Derris scandens (Roxb.) Benth. (DS) contains genistein-7-O-[alpha-rhamnopyranosyl-(1 -> 6)]-beta-glucopyranoside (GTG), which is a unique marker. Previous analyses of GTG using antibody-based immunoassays were compromised because of their high cross-reactivity with structurally related compounds of DS, thereby limiting their applicability in DS quality control.Objective: Conjugation of GTG with carrier proteins was achieved using the Mannich reaction to produce a highly specific monoclonal antibody (mAb) targeting GTG (anti-GTG mAb).Methods: The anti-GTG mAb was generated using hybridoma technology and characterised using an indirect competitive enzyme-linked immunosorbent assay (icELISA). Both lateral-flow immunoassay (LFIA) and icELISA were developed to detect and quantify GTG in DS raw materials and associated products.Results: icELISA using the anti-GTG mAb showed 100% specificity for GTG, with only 1.77% cross-reactivity with genistin and less than 0.01% cross-reactivity with other compounds. icELISA demonstrated a linear range for GTG determination between 62.5 and 2000 ng/mL. The limits of detection (LOD) and quantification were 49.68 and 62.50 ng/mL for GTG, respectively. The precision of the analysis ranged from 1.28% to 4.20% for repeatability and from 1.03% to 7.05% for reproducibility. The accuracy of the analysis ranged from 101.97% to 104.01% for GTG recovery. GTG levels determined via icELISA were consistent with those confirmed via high-performance liquid chromatography (HPLC) (R-2 = 0.9903). Moreover, the LOD of LFIA for GTG was 500 ng/mL.Conclusion: Immunoassays utilising specific anti-GTG mAbs were successfully developed, including LFIA for rapid GTG detection and icELISA for GTG quantification.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据