4.5 Article

Differentiating interstitial lung diseases from other respiratory diseases using electronic nose technology

期刊

RESPIRATORY RESEARCH
卷 24, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s12931-023-02575-3

关键词

Breath test; Diagnostic test; Biomarker; Electronic nose; Interstitial lung diseases; Obstructive lung disease; Lung cancer

向作者/读者索取更多资源

The study used eNose technology to analyze patients' breath profiles and found that the breath of ILD patients was significantly different from patients with other respiratory diseases, indicating high potential for accurately distinguishing ILD patients with this technology.
IntroductionInterstitial lung disease (ILD) may be difficult to distinguish from other respiratory diseases due to overlapping clinical presentation. Recognition of ILD is often late, causing delay which has been associated with worse clinical outcome. Electronic nose (eNose) sensor technology profiles volatile organic compounds in exhaled breath and has potential to detect ILD non-invasively. We assessed the accuracy of differentiating breath profiles of patients with ILD from patients with asthma, chronic obstructive pulmonary disease (COPD), and lung cancer using eNose technology.MethodsPatients with ILD, asthma, COPD, and lung cancer, regardless of stage or treatment, were included in a cross-sectional study in two hospitals. Exhaled breath was analysed using an eNose (SpiroNose) and clinical data were collected. Datasets were split in training and test sets for independent validation of the model. Data were analyzed with partial least squares discriminant and receiver operating characteristic analyses.Results161 patients with ILD and 161 patients with asthma (n = 65), COPD (n = 50) or lung cancer (n = 46) were included. Breath profiles of patients with ILD differed from all other diseases with an area under the curve (AUC) of 0.99 (95% CI 0.97-1.00) in the test set. Moreover, breath profiles of patients with ILD could be accurately distinguished from the individual diseases with an AUC of 1.00 (95% CI 1.00-1.00) for asthma, AUC of 0.96 (95% CI 0.90-1.00) for COPD, and AUC of 0.98 (95% CI 0.94-1.00) for lung cancer in test sets. Results were similar after excluding patients who never smoked.ConclusionsExhaled breath of patients with ILD can be distinguished accurately from patients with other respiratory diseases using eNose technology. eNose has high potential as an easily accessible point-of-care medical test for identification of ILD amongst patients with respiratory symptoms, and could possibly facilitate earlier referral and diagnosis of patients suspected of ILD.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据