4.5 Article

Lipid profiling of electrosurgical vapors for real-time assistance of soft tissue sarcoma resection

期刊

JOURNAL OF SURGICAL ONCOLOGY
卷 -, 期 -, 页码 -

出版社

WILEY
DOI: 10.1002/jso.27502

关键词

mass sprectrometry; molecular profiling; real-time mass spectrometry

向作者/读者索取更多资源

Lipid profiling by REIMS can accurately discriminate and identify different soft tissue sarcomas from normal tissues, providing a potential asset to improve surgical resection of soft tissue sarcomas in the future.
BackgroundSoft tissue sarcomas (STS) constitute a heterogeneous group of rare tumor entities. Treatment relies on challenging patient-tailored surgical resection. Real-time intraoperative lipid profiling of electrosurgical vapors by rapid evaporative ionization mass spectrometry (REIMS) may aid in achieving successful surgical R0 resection (i.e., microscopically negative-tumor margin resection). Here, we evaluate the ex vivo accuracy of REIMS to discriminate and identify various STS from normal surrounding tissue.MethodsTwenty-seven patients undergoing surgery for STS at Maastricht University Medical Center+ were included in the study. Samples of resected STS specimens were collected and analyzed ex vivo using REIMS. Electrosurgical cauterization of tumor and surrounding was generated successively in both cut and coagulation modes. Resected specimens were subsequently processed for gold standard histopathological review. Multivariate statistical analysis (principal component analysis-linear discriminant analysis) and leave-one patient-out cross-validation were employed to compare the classifications predicted by REIMS lipid profiles to the pathology classifications. Electrosurgical vapors produced during sarcoma resection were analyzed in vivo using REIMS.ResultsIn total, 1200 histopathologically-validated ex vivo REIMS lipid profiles were generated from 27 patients. Ex vivo REIMS lipid profiles classified STS and normal tissues with 95.5% accuracy. STS, adipose and muscle tissues were classified with 98.3% accuracy. Well-differentiated liposarcomas and adipose tissues could not be discriminated based on their respective lipid profiles. Distinction of leiomyosarcomas from other STS could be achieved with 96.6% accuracy. In vivo REIMS analyses generated intense mass spectrometric signals.ConclusionLipid profiling by REIMS is able to discriminate and identify STS with high accuracy and therefore constitutes a potential asset to improve surgical resection of STS in the future.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据