4.4 Article

Automatic Rejection based on Tissue Signal (ARTS) for motion-corrected quantification of cerebral venous oxygenation in neonates and older adults

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Biophysics

Toward vendor-independent measurement of cerebral venous oxygenation: Comparison of TRUST MRI across three major MRI manufacturers and association with end-tidal CO2

Abubakr Eldirdiri et al.

Summary: The study aimed to evaluate the reproducibility of TRUST Y-v measurements across MRI scanners from different vendors and examine the correlation between Y-v and EtCO2 in a multisite, multivendor setting. Standardized TRUST pulse sequences were implemented on three scanners, and ten healthy subjects were scanned. The results showed no significant bias in Y-v measurements across the scanners and a strong correlation between Y-v and EtCO2. In conclusion, the standardized TRUST sequences can accurately and reproducibly measure Y-v across different MRI scanners, and recording EtCO2 can complement Y-v measurement to account for CO2-related physiological fluctuations.

NMR IN BIOMEDICINE (2023)

Article Neurosciences

Affine image registration of arterial spin labeling MRI using deep learning networks

Zongpai Zhang et al.

Summary: In this study, a CNN-based affine registration network (ARN) was proposed for registration of low-SNR 3D ASL perfusion image time series, and its performance was compared with the state-of-the-art SPM algorithm. The results showed that the ARN method outperformed SPM in terms of registration accuracy and speed, and can be generalized to different scanners and image resolutions of ASL perfusion images.

NEUROIMAGE (2023)

Article Hematology

Cerebral oxygen metabolic stress is increased in children with sickle cell anemia compared to anemic controls

Melanie E. Fields et al.

Summary: This study found that children with sickle cell anemia (SCA) experience elevated oxygen extraction fraction (OEF) in the whole brain compared to anemic controls (AC) and healthy controls (HC). After controlling for the impact of anemia, SCA patients still show higher OEF levels, indicating that there may be other pathophysiological factors contributing to cerebral metabolic stress in these children.

AMERICAN JOURNAL OF HEMATOLOGY (2022)

Review Radiology, Nuclear Medicine & Medical Imaging

Cerebral oxygen extraction fraction MRI: Techniques and applications

Dengrong Jiang et al.

Summary: This article reviews the emerging MRI-based techniques for measuring oxygen extraction fraction (OEF) in the human brain. OEF is an important physiological parameter in brain function and metabolism. Compared to other methods, MRI techniques are non-invasive, radiation-free, and more widely available.

MAGNETIC RESONANCE IN MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Validation of T2-based oxygen extraction fraction measurement with15O positron emission tomography

Dengrong Jiang et al.

Summary: The study evaluated the accuracy of T-2-based whole-brain oxygen extraction fraction (OEF) estimation by comparing it with gold standard(15)O-PET measurements. The results showed that TRUST MRI provided accurate quantification of whole-brain OEF noninvasively, with highly comparable accuracy and reproducibility compared to (15)O-PET.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Three-dimensional assessment of brain arterial compliance: Technical development, comparison with aortic pulse wave velocity, and age effect

Yang Li et al.

Summary: The study aimed to develop an MRI technique for measuring VC and arterial wall pulsation in major intracranial vessels, with the VaCom-PCASL technique showing optimized reconstruction parameters and labeling duration. Additionally, a significant correlation was found between intracranial VC and aortic pulse wave velocity, showing lower vascular compliance in the older age group compared to the younger group.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Endocrinology & Metabolism

Elevated brain oxygen extraction fraction measured by MRI susceptibility relates to perfusion status in acute ischemic stroke

Audrey P. Fan et al.

JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Brain Oxygen Extraction Is Differentially Altered by Alzheimer's and Vascular Diseases

Dengrong Jiang et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2020)

Article Neurosciences

Multiparametric measurement of cerebral physiology using calibrated fMRI

Molly G. Bright et al.

NEUROIMAGE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Quantification of intracranial arterial blood flow using noncontrast enhanced 4D dynamic MR angiography

Xingfeng Shao et al.

MAGNETIC RESONANCE IN MEDICINE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Differential cerebral hemometabolic responses to blood transfusions in adults and children with sickle cell anemia

Meher R. Juttukonda et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2019)

Article Endocrinology & Metabolism

Hemodynamic mechanisms underlying elevated oxygen extraction fraction (OEF) in moyamoya and sickle cell anemia patients

Jennifer M. Watchmaker et al.

JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Enhancement of automated blood flow estimates (ENABLE) from arterial spin-labeled MRI

Zahra Shirzadi et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Cross-vendor harmonization of T2-relaxation-under-spin-tagging (TRUST) MRI for the assessment of cerebral venous oxygenation

Dengrong Jiang et al.

MAGNETIC RESONANCE IN MEDICINE (2018)

Article Endocrinology & Metabolism

Reduced global brain metabolism but maintained vascular function in amnestic mild cognitive impairment

Binu P. Thomas et al.

JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Structural Correlation-based Outlier Rejection (SCORE) algorithm for arterial spin labeling time series

Sudipto Dolui et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2017)

Article Biophysics

Susceptibility-based time-resolved wholeorgan and regional tissue oximetry

Felix W. Wehrli et al.

NMR IN BIOMEDICINE (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Assessing the effects of subject motion on T2 relaxation under spin tagging (TRUST) cerebral oxygenation measurements using volume navigators

Jeffrey N. Stout et al.

MAGNETIC RESONANCE IN MEDICINE (2017)

Article Neuroimaging

Application of calibrated fMRI in Alzheimer's disease

Isabelle Lajoie et al.

NEUROIMAGE-CLINICAL (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Multisite Evaluations of a T2-Relaxation-Under-Spin-Tagging (TRUST) MRI Technique to Measure Brain Oxygenation

Peiying Liu et al.

MAGNETIC RESONANCE IN MEDICINE (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

T1 and T2 Values of Human Neonatal Blood at 3 Tesla: Dependence on Hematocrit, Oxygenation, and Temperature

Peiying Liu et al.

MAGNETIC RESONANCE IN MEDICINE (2016)

Article Neurosciences

Altered Resting-State Connectivity in Huntington's Disease

Cornelius J. Werner et al.

HUMAN BRAIN MAPPING (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Testretest reproducibility of a rapid method to measure brain oxygen metabolism

Peiying Liu et al.

MAGNETIC RESONANCE IN MEDICINE (2013)

Article Endocrinology & Metabolism

Characterizing brain oxygen metabolism in patients with multiple sclerosis with T2-relaxation-under-spin-tagging MRI

Yulin Ge et al.

JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM (2012)

Review Radiology, Nuclear Medicine & Medical Imaging

4D flow MRI

Michael Markl et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

Calibration and validation of TRUST MRI for the estimation of cerebral blood oxygenation

Hanzhang Lu et al.

MAGNETIC RESONANCE IN MEDICINE (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

A Fast, Effective Filtering Method for Improving Clinical Pulsed Arterial Spin Labeling MRI

Huan Tan et al.

JOURNAL OF MAGNETIC RESONANCE IMAGING (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Empirical optimization of ASL data analysis using an ASL data processing toolbox:: ASLtbx

Ze Wang et al.

MAGNETIC RESONANCE IMAGING (2008)

Article Radiology, Nuclear Medicine & Medical Imaging

Quantitative evaluation of oxygenation in venous vessels using T2-Relaxation-Under-Spin-Tagging MRI

Hanzhang Lu et al.

MAGNETIC RESONANCE IN MEDICINE (2008)