Optimization of Y-90 Radioembolization Imaging for Post-Treatment Dosimetry on a Long Axial Field-of-View PET/CT Scanner

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Radiology, Nuclear Medicine & Medical Imaging

Application of the long axial field-of-view PET/CT with low-dose [18F]FDG in melanoma

Christos Sachpekidis et al.

Summary: The study aims to determine an appropriate acquisition time range for the new long axial field of view Biograph Vision Quadra PET/CT scanner in melanoma patients. The results show that low-dose LAFOV PET/CT imaging is feasible and can provide comparable diagnostic data to standard lengths of acquisition in a shorter scanning time, which is significant for the diagnostic work-up of melanoma patients.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

Phantom-based evaluation of yttrium-90 datasets using biograph vision quadra

Konstantinos G. Zeimpekis et al.

Summary: This study evaluates the image quality characteristics of two NEMA phantoms with Y-90 on a long AFOV PET/CT and identifies the optimized reconstruction setup for imaging patients with hepatocellular carcinoma after Y-90 radioembolization. The results show that a 20-minute reconstruction time provides images with acceptable signal-to-noise ratio.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

EFOMP?s protocol quality controls in PET/CT and PET/MR

Roberta Matheoud et al.

Summary: This article presents the protocol on Quality Controls in PET/CT and PET/MRI published by EFOMP in May 2022. The protocol provides simple and practical procedures for identifying changes in system performance and maintaining quality. It includes quality control procedures for various systems and parameters directly linked to image quality. A regular QC based on this protocol ensures optimal conditions and performance for clinical tasks.

PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

Characterization of the partial volume effect along the axial field-of-view of the Biograph Vision Quadra total-body PET/CT system for multiple isotopes

Julia G. Mannheim et al.

Summary: The study aimed to determine the contrast recovery coefficients (CRCs) and voxel noise levels for multiple isotopes throughout the 1.06 m axial field of view (FOV) of the Biograph Vision Quadra PET/CT system. Cylindrical phantoms with different sphere sizes and isotopes were used to evaluate the partial volume effect (PVE). The results showed distinct differences in PVE within the FOV, which can significantly affect the quantitative analysis of patient data. MRD322 resulted in slightly lower CRC values and significantly reduced voxel noise compared to MRD85.

EJNMMI PHYSICS (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

Impact of the maximum ring difference on image quality and noise characteristics of a total-body PET/CT scanner

F.P. Schmidt et al.

Zeitschrift fur Medizinische Physik (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

EANM procedure guideline for the treatment of liver cancer and liver metastases with intra-arterial radioactive compounds

M. Weber et al.

Summary: Primary and secondary liver tumors can be treated with radioembolization, and personalized dosimetry helps improve response rates. The decision for radioembolization should be made by a multidisciplinary tumour board based on clinical guidelines.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Radioembolization Dosimetry with Total-Body 90Y PET

Gustavo Costa et al.

Summary: This study aimed to evaluate the suitability of using total-body Y-90 PET with the uEXPLORER scanner for liver dosimetry and investigate possible improvements in TARE Y-90 PET-based dosimetry. The results showed good agreement between the uEXPLORER and mCT in terms of total liver-absorbed dose, with the uEXPLORER demonstrating higher signal-to-noise ratio and lower image noise, which is expected to improve dose quantification and tumor dosimetry.

JOURNAL OF NUCLEAR MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Abbreviated scan protocols to capture 18F-FDG kinetics for long axial FOV PET scanners

Varsha Viswanath et al.

Summary: Kinetic parameters from dynamic F-18-fluorodeoxyglucose (FDG) imaging provide complementary insights for the study of diseases compared to static clinical imaging. Long axial field-of-view (LAFOV) PET scanners have advantages over standard axial field-of-view (SAFOV) scanners, including the ability to perform multi-organ dynamic imaging in a single bed position and the potential for abbreviated dynamic imaging protocols. This study demonstrates that dynamic imaging for 10-15 minutes immediately post-injection, followed by a 5-minute scan at 1-hour post-injection, can accurately and precisely quantify F-18-FDG on a long axial FOV scanner, potentially allowing for more widespread use of dynamic F-18-FDG imaging.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Performance Characteristics of the Biograph Vision Quadra PET/CT System with a Long Axial Field of View Using the NEMA NU 2-2018 Standard

George A. Prenosil et al.

Summary: The performance of the Biograph Vision Quadra PET/CT system was evaluated in this study. The system showed improved sensitivity and count rates compared to the Biograph Vision 600 due to its larger field of view. The physical performance and image quality were assessed through various experiments and compared with existing PET scanners.

JOURNAL OF NUCLEAR MEDICINE (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

EARL compliance and imaging optimisation on the Biograph Vision Quadra PET/CT using phantom and clinical data

Joyce van Sluis et al.

Summary: This study explores the compliance of the Siemens Biograph Vision Quadra PET/CT system with EARL specifications for F-18-FDG tumor imaging in LAFOV systems. Additional tests and clinical data were used to validate the effects of reducing scan duration on image accuracy and noise.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

Image quality assessment along the one metre axial field-of-view of the total-body Biograph Vision Quadra PET/CT system for 18F-FDG

Ivo Rausch et al.

Summary: This study aimed to assess the extent of useful aFOV of the Biograph Vision Quadra PET/CT system, with results showing stable image noise and contrast within the central 80 cm but increasing variability and noise beyond this range, particularly evident at short acquisition times.

EJNMMI PHYSICS (2022)

Article Engineering, Biomedical

The OpenGATE ecosystem for Monte Carlo simulation in medical physics

David Sarrut et al.

Summary: This paper reviews the ecosystem of GATE, an open-source Monte Carlo toolkit for medical physics. It describes the principal modules and key concepts of GATE, as well as the main source code repositories and the automated compilation and testing processes. The collaborative development of OpenGATE over the past 20 years is presented, along with the impact of GATE on medical physics and cancer research.

PHYSICS IN MEDICINE AND BIOLOGY (2022)

Article Radiology, Nuclear Medicine & Medical Imaging

International recommendations for personalised selective internal radiation therapy of primary and metastatic liver diseases with yttrium-90 resin microspheres

Hugo Levillain et al.

Summary: This study established recommendations for the optimisation of selective internal radiation therapy (SIRT) with yttrium-90 (Y-90)-resin microspheres, based on expert panel discussions and survey responses from leading experts in the field. The recommendations cover various aspects of SIRT, including activity prescription, post-treatment dosimetry, and imaging for treatment verification. It is recommended that a multidisciplinary team define treatment strategy and therapeutic intent, and that a personalised approach using dosimetry be adopted for activity prescription. Additionally, post-SIRT imaging and dosimetry are strongly recommended for treatment verification and assessment.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2021)

Article Multidisciplinary Sciences

Evaluation of qualitative and quantitative data of Y-90 imaging in SPECT/CT and PET/CT phantom studies

Agata Kubik et al.

Summary: The feasibility of SPECT and PET Y-90 imaging was assessed by visualizing hot and cold foci in phantoms with varying isotope concentrations. PET imaging provided better results than Bremsstrahlung based SPECT imaging, indicating its potential as the method of choice in Y-90 post radioembolization imaging.

PLOS ONE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

EANM dosimetry committee series on standard operational procedures: a unified methodology for 99mTc-MAA pre- and 90Y peri-therapy dosimetry in liver radioembolization with 90Y microspheres

Carlo Chiesa et al.

Summary: The standard operational procedure aims to standardize the evaluation methodology for absorbed dose calculations in Y-90 microsphere liver radioembolization. Treatment planning based on average absorbed dose is advised, with distinct evaluation between target tumors and non-tumoral tissue being vital for proper therapy optimization. Various imaging methodologies such as SPECT/CT and PET/CT are recommended for accurate dosimetry calculations.

EJNMMI PHYSICS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of the Biograph Vision and Biograph mCT for quantitative Y-90 PET/CT imaging for radioembolisation

Britt Kunnen et al.

EJNMMI PHYSICS (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Multicentre quantitative 68Ga PET/CT performance harmonisation

Daphne M. V. Huizing et al.

EJNMMI PHYSICS (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Dose volume histogram-based optimization of image reconstruction parameters for quantitative 90Y-PET imaging

Wendy Siman et al.

MEDICAL PHYSICS (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

IDAC-Dose 2.1, an internal dosimetry program for diagnostic nuclear medicine based on the ICRP adult reference voxel phantoms

Martin Andersson et al.

EJNMMI RESEARCH (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

Selective internal radiation therapy in patients with progressive neuroendocrine liver metastases

Charlotte Ebeling Barbier et al.

EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Comparison of quantitative Y-90 SPECT and non-time-of-flight PET imaging in post-therapy radioembolization of liver cancer

Jianting Yue et al.

MEDICAL PHYSICS (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Abdo-Man: a 3D-printed anthropomorphic phantom for validating quantitative SIRT

Jonathan I. Gear et al.

EJNMMI PHYSICS (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Systematic Evaluation of Tumoral Tc-99m-MAA Uptake Using SPECT and SPECT/CT in 502 Patients Before Y-90 Radioembolization

Harun Ilhan et al.

JOURNAL OF NUCLEAR MEDICINE (2015)

Article Radiology, Nuclear Medicine & Medical Imaging

PET optimization for improved assessment and accurate quantification of 90Y-microsphere biodistribution after radioembolization

Josep M. Marti-Climent et al.

MEDICAL PHYSICS (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

90Y PET-based dosimetry after selective internal radiotherapy treatments

Marco D'Arienzo et al.

NUCLEAR MEDICINE COMMUNICATIONS (2012)

Article Radiology, Nuclear Medicine & Medical Imaging

MIRD Pamphlet No. 21: A Generalized Schema for Radiopharmaceutical Dosimetry-Standardization of Nomenclature

Wesley E. Bolch et al.

JOURNAL OF NUCLEAR MEDICINE (2009)

Article Chemistry, Inorganic & Nuclear

A new internal pair production branching ratio of 90Y:: The development of a non-destructive assay for 90Y and 90Sr

R. G. Selwyn et al.

APPLIED RADIATION AND ISOTOPES (2007)