4.7 Article

Quantifying heat losses from experimental setup and their effect on annular channel heat flux using CFD

期刊

出版社

ELSEVIER FRANCE-EDITIONS SCIENTIFIQUES MEDICALES ELSEVIER
DOI: 10.1016/j.ijthermalsci.2023.108766

关键词

-

向作者/读者索取更多资源

We have developed an advanced experimental setup to investigate flow and heat transfer in an annular channel. The setup allows heat transfer measurements and flow visualization using a temperature-controlled inner tube. Measurements can be conducted in both single-phase and two-phase flow regimes. The setup ensures a uniform velocity field in the annular channel using specially designed inlet and outlet headers. The inner copper tube is heated by water and contains turbulators for enhanced heat transfer and thermocouples for temperature measurement. A three-dimensional conjugate heat transfer CFD model has been developed and validated to accurately estimate heat losses in the setup. This study demonstrates the importance of numerical simulations in improving the interpretation of complex experimental results.
An advanced experimental setup in the form of a double-pipe heat exchanger has been developed to investigate various flow and heat transfer regimes in an annular channel. The experimental setup is designed for heat transfer measurements and flow visualization in a transparent annular channel with temperature-controlled heating of the inner tube. It allows measurements in both, single-phase and two-phase (boiling) flow regimes. The transparent annular channel is connected at the front and rear end by specially designed inlet and outlet headers, which ensure a uniform velocity field of the coolant (primary fluid) in the annular channel. The heating water (secondary fluid) heats the inner tube made of copper, which contains unique turbulators positioned equidistantly. These are designed to enhance the heat transfer on the inner side of the copper tube and to accommodate the thermocouples measuring the surface temperature of the tube. The main purpose of this study is to assess as accurately as possible the influence of heat losses in the experimental setup on the heat fluxes in the transparent annular channel. Therefore, it is necessary to accurately estimate the heat losses at the inlet and outlet header, upstream and downstream of the annular section. To this end, a detailed three-dimensional conjugate heat transfer CFD model has been developed and validated with a series of single-phase measurements, including the measured temperatures in both headers and the temperature profile along the heated inner copper tube. The simulated velocity and temperature fields have been used to quantify the heat flux distribution in the experimental setup. This study clearly demonstrates that properly validated numerical simulations can provide missing experimental information and significantly improve the interpretation of complex experimental results.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据