This paper proposes a method that applies a combined stereo adjustment model to estimate the collapse height of buildings during earthquakes and thoroughly verifies its feasibility through experiments. By using laser altimetry points and tie points from HRSSIs, the stereoscopic positioning accuracy of HRSSIs is improved. Then, an automatic building corners extraction method is used to assess building damage based on the height change of building corners. The experimental results indicate that the proposed method can accurately assess the degree of building damage.
Accurately estimating the collapse height of buildings during earthquakes holds great significance. Acquiring precise height information of buildings using dual-phase high-resolution stereo satellite images (HRSSIs) requires high-precision ground control points, which are difficult to obtain in earthquake-stricken areas. Spaceborne laser data has been validated to significantly improve the vertical accuracy of HRSSIs. Therefore, this paper first proposes the application of a combined stereo adjustment model in building collapse estimation and thoroughly verifies its feasibility. Firstly, the laser altimetry points (LAPs) acquired by GF-7 and ICESat-1 serve as elevation control points (ECPs), and the tie points from HRSSIs were used as constraint to conduct combined adjustment to improve the consistency of stereoscopic positioning accuracy between HRSSIs before and after the earthquake. Subsequently, a footprints-to-conners, coarse-to-fine, automatic building corners extraction method was performed. Avoiding the time-consuming generation of large-scale DSM while also improving the accuracy of building collapse assessment. Finally, according to the height change of building corners calculated from HRSSIs, building damage assessment was completed. According to the above methods, independent experiments were carried out respectively for the Oaxaca earthquake in Mexico in 2020 and the Kahramanmaras earthquake in Turkiye in 2023. GF-7 HRSSIs was used to verify the accuracy and stability of the proposed method for 3D assessment of building damage. The results indicate that the RMSE of elevation positioning accuracy has been greatly reduced in both regions, ranging from 10.29 m to 0.95 m and from 6.67 m to 0.99 m, respectively. This accuracy guarantees the feasibility of detecting the building floor-level collapse. And 2541 building corner points were extracted from two disaster areas, with correct corner points accounting for 85.18%. A total of 520 buildings were correctly extracted corner points, with an accuracy rate of 94.12% for assessing the degree of damage.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据