4.5 Article

Comparing remote and face-to-face assessments of physical performance in older adults: A reliability study

期刊

GERIATRIC NURSING
卷 55, 期 -, 页码 71-78

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.gerinurse.2023.11.004

关键词

Physical performance; Online assessment; Older people; Reliability; Validity

向作者/读者索取更多资源

This study demonstrates that remote physical performance measurements of older adults exhibit consistently high levels of relative reliability compared to face-to-face measurements. Additionally, certain remote evaluations show acceptable absolute reliability.
Introduction: Older people often experience a decline in their physical performance. Tests have been approved to evaluate this performance in person. Yet, the constraints associated with in-person assessments (e.g. lack of medical facilities, pandemic lockdown, and contagion risk) are making us contemplate setting up assessments remotely.Objectives: To determine whether remote physical performance measurements of older adults are reliable and valid compared to face-to-face measurements.Methods: Forty-five subjects aged 65 and over completed the normal/fast speed test (NWT/FWT), the unipodal balance test (UBT), the normal/fast timed up and go test (NTUG/FTUG), the 5 and 10 rep sit to stand test (5STS and 10STS), the 30 sec chair stand (30CS), the 2 minute step test (2MST) and the flexibility before standing (SAD) once face-to-face and twice remotely, by two different observers. The intraclass correlation coefficients (ICC), the standard errors of measurement (SEM%) and minimum detectable changes (MDC%) were calculated for both intra- and inter-observer conditions, to assess the relative and the absolute reliability. An ICC value exceeding 0.90 indicates a very high reliability, while an ICC between 0.70 and 0.89 signifies a high reliability. In clinical practice, a SEM % of less than 10% is considered acceptable. A smaller MDC % indicates a measurement that is more sensitive to detecting changes.Results: Intra-observer relative reliability was very high (ICC>0.9) for the UBT, NWT, NTUG, FTUG, 5STS, 10STS, 30CS and the SAD; and high (ICC>0.7) for the 2MST and FWS. SEM% values ranged from 0% to 24.03% and MDC from 0% to 9.93%. Inter-observer relative reliability was considered very high (ICC>0.9) for all tests. SEM% values ranged from 0% to 17.68% and MDC from 0% to 7.32%.Conclusion: Our findings demonstrate that remote assessments exhibited consistently high to very high levels of intra- and inter-observer relative reliability when compared to face-to-face assessments. Additionally, certain remote evaluations showed acceptable absolute reliability, making them viable alternatives for healthcare professionals when in-person assessments are not feasible in clinical practice.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据