This exploratory study aimed to investigate the dynamic changes in lower limb muscles using ultrasound shear wave elastography as a marker for early lower limb ischemia in patients supported with veno-arterial extracorporeal membrane oxygenation (VA-ECMO).
Background and objectives Limb ischemia or compartment syndrome, requiring surgery, are some of the frequent cannula-related complications in patients supported with veno-arterial extracorporeal membrane oxygenation (VA-ECMO). The purpose of this exploratory study is to depict and evaluate the dynamic changes in the lower limb muscles with ultrasound shear wave elastography as marker for early lower limb ischemia.Methods Eleven patients with VA-ECMO after cardiac arrest were included in this study. Seven patients received distal perfusion cannula (DPC) after implantation of the VA-ECMO, whereas 4 had no DPC after VA-ECMO. Compartment syndrome was clinically excluded in all patients. Both lower limbs, e.g., with and without arterial cannula, were monitored with near-infrared spectroscopy (NIRS) for the oxygen saturation of the local tissue. We performed ultrasound shear wave elastrography (SWE) to assess dynamic changes of the medial gastrocnemius muscle at maximum passive muscle stretch (exercise) of both legs. Color-coded duplexsonography was conducted to examine the blood flow velocity of the popliteal artery of the lower limb.Results We found no difference between DPC and no DPC (p = 0.115) during use of VA-ECMO. However, we detected marked lower limb muscle perfusion deficits of cannulated (58.9 +/- 13.5 kPa) vs. cannula-free limb (95.7 +/- 27.9 kPa: p < 0.001), applying SWE. No relationship was detected between NIRS measurements and SWE values (kPa) of both lower limbs. The mean peak systolic velocity of the popliteal artery at the cannulated side (30.0 +/- 11.7 cm/s) was reduced compared to the non-cannulated side (39.3 +/- 18.6 cm/s; p = 0.054).Conclusions Regardless of DPC after implantation of VA-ECMO, the gastrocnemius muscles seem to lose function due to cannula-related microcirculatory deficits. Muscle function analysis via SWE combined with NIRS might offer a sensitive indicator for early onset leg ischemia during VA-ECMO-related arterial cannulation.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据