4.7 Article

Diffusion MRI with free gradient waveforms on a high-performance gradient system: Probing restriction and exchange in the human brain

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Radiology, Nuclear Medicine & Medical Imaging

Measuring water exchange on a preclinical MRI system using filter exchange and diffusion time dependent kurtosis imaging

Chenyang Li et al.

Summary: FEXI and DKI(t) show similar sensitivity to exchange processes in white matter but are affected by tissue microstructure in gray matter.

MAGNETIC RESONANCE IN MEDICINE (2023)

Article Radiology, Nuclear Medicine & Medical Imaging

Time-dependent diffusivity and kurtosis in phantoms and patients with head and neck cancer

Eddy Solomon et al.

Summary: The reliability of measuring diffusivity, diffusional kurtosis, and cellular-interstitial water exchange time with long diffusion times using stimulated-echo DWI was assessed. The study found that time-dependent diffusion MRI measurements can provide stable diffusion and kurtosis values over a wide range of diffusion times and across multiple MRI systems. Additionally, the Karger model can be used to estimate cellular-interstitial water exchange time in metastatic lymph nodes.

MAGNETIC RESONANCE IN MEDICINE (2023)

Article Neurosciences

Diffusion time dependence, power-law scaling, and exchange in gray matter

Jonas L. Olesen et al.

Summary: This article discusses the characterization of neural tissue microstructure and the issue of specificity of dMRI signals, as well as experimental validation of biophysical models for white and gray matter cells.

NEUROIMAGE (2022)

Article Physics, Multidisciplinary

Stay on the Beat With Tensor-Valued Encoding: Time-Dependent Diffusion and Cell Size Estimation in ex vivo Heart

Samo Lasic et al.

Summary: Diffusion encoding with free gradient waveforms can provide increased microstructural specificity. In cardiac applications, considering the effects of time-dependent diffusion and using different b-tensor shapes and motion compensation can provide additional tissue information.

FRONTIERS IN PHYSICS (2022)

Article Neurosciences

Neurite Exchange Imaging ((NEXI): A minimal model of diffusion in gray matter with inter-compartment water exchange

Ileana O. Jelescu et al.

Summary: Research focuses on diffusion MRI in gray matter, proposing Neurite Exchange Imaging (NEXI) as a more suitable model, with in vivo experiments showing the essential role of water exchange in interpreting diffusion MRI measurements in gray matter.

NEUROIMAGE (2022)

Article Neurosciences

Mapping the human connectome using diffusion MRI at 300 mT/m gradient strength: Methodological advances and scientific impact

Qiuyun Fan et al.

Summary: In the past decade, tremendous efforts have been made to advance cutting-edge MRI technology in order to map the structural connectivity in the living human brain. This review article summarizes the technical developments in using the Connectom scanner for large-scale and scientific studies of the human brain, and discusses the scientific impact of the Connectom MRI scanner.

NEUROIMAGE (2022)

Article Biophysics

What does FEXI measure?

Mohammad Khateri et al.

Summary: Filter-exchange imaging (FEXI) is a method used for evaluating the permeability of cell membranes, relying on suppressing extracellular signals and monitoring diffusivity recovery. Monte Carlo simulations show that FEXI is sensitive to both transcytolemmal exchange and compartment geometry.

NMR IN BIOMEDICINE (2022)

Article Biophysics

Improving MR cell size imaging by inclusion of transcytolemmal water exchange

Xiaoyu Jiang et al.

Summary: The goal of this study is to include transcytolemmal water exchange in MR cell size imaging using the IMPULSED model for more accurate characterization of tissue cellular properties and quantification of indicators of water exchange. A heuristic model is proposed to incorporate water exchange into the IMPULSED model, improving the accuracy of cell size and apparent volume fraction of intracellular space parameters.

NMR IN BIOMEDICINE (2022)

Review Biochemical Research Methods

Microstructure with diffusion MRI: what scale we are sensitive to?

Valerij G. Kiselev

Summary: The review highlights the importance of balancing measurability against interpretability in evaluating cellular tissue architecture using diffusion MRI techniques. Advances in modern measurement techniques are discussed within the overarching idea of matching diffusion weighting to the geometry of targeted cell species.

JOURNAL OF NEUROSCIENCE METHODS (2021)

Review Biochemical Research Methods

The present and the future of microstructure MRI: From a paradigm shift to normal science

Dmitry S. Novikov

Summary: Utilizing MRI to reveal tissue microstructures holds great potential, although this concept is not entirely new, its applications in neuroscience and neuroradiology are only just beginning to gain widespread attention. Research is focused on coarse-graining tissue structures and utilizing various diffusion models and phenomena to interpret MRI results.

JOURNAL OF NEUROSCIENCE METHODS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

MRI-cytometry: Mapping nonparametric cell size distributions using diffusion MRI

Junzhong Xu et al.

Summary: The study presents a new MRI-cytometry method for noninvasively mapping nonparametric cell size distributions in tissues. Results from simulations and experiments confirm the reliability of the method in mapping cell size distributions, with potential applications in breast cancer patients.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Biochemical Research Methods

Gradient waveform design for tensor-valued encoding in diffusion MRI

Filip Szczepankiewicz et al.

Summary: Tensor-valued diffusion encoding allows for controlling sensitivity to microscopic diffusion anisotropy through modulating the shape of the b-tensor, which serves as a new encoding dimension. When designing gradient waveforms, considerations include hardware and physiological limitations, potential confounding effects not captured by the b-tensor, and artifacts related to diffusion encoding.

JOURNAL OF NEUROSCIENCE METHODS (2021)

Article Neurosciences

Accuracy and precision in super-resolution MRI: Enabling spherical tensor diffusion encoding at ultra-high b-values and high resolution

Geraline Vis et al.

Summary: Super-resolution reconstruction in diffusion MRI improves signal accuracy by balancing spatial resolution and diffusion encoding strength effectively. However, the relationship between precision and acquisition, reconstruction, and intrinsic tissue parameters is more complex, showing substantial gain in precision only when sacrificing some spatial resolution.

NEUROIMAGE (2021)

Article Neurosciences

Connectome 2.0: Developing the next-generation ultra-high gradient strength human MRI scanner for bridging studies of the micro-, meso- and macro-connectome

Susie Y. Huang et al.

Summary: The Human Connectome Project marked advancements in MRI technology for mapping the structural connections of the human brain, showcasing the potential of high-gradient performance scanners for studying neural tissue microstructure. The development of the next-generation Connectome scanner aims to optimize the study of neural tissue microstructure and connectional anatomy, pushing diffusion resolution to unprecedented levels and creating an ultimate diffusion MRI instrument capable of capturing the multi-scale organization of the living human brain.

NEUROIMAGE (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Evidence for microscopic kurtosis in neural tissue revealed by correlation tensor MRI

Rafael Neto Henriques et al.

Summary: Correlation tensor imaging (CTI) with improved double diffusion encoding experiments estimated microscopic diffusional kurtosis (mu K) in in vivo rat brains, showing mu K is a dominant kurtosis source in healthy white and gray matter tissues and can bias prior multi-gaussian component analyses.

MAGNETIC RESONANCE IN MEDICINE (2021)

Article Clinical Neurology

Time-dependent diffusion MRI probes cerebellar microstructural alterations in a mouse model of Down syndrome

Dan Wu et al.

Summary: The study demonstrated the superior sensitivity of utilizing oscillating gradient dMRI to detect cerebellar microstructural changes in Down syndrome mice. The detection sensitivity increased with oscillating frequency, and the t(d)-dependence was reduced in Ts65Dn mice, likely due to altered granule cell density and abnormal dendritic arborization of Purkinje cells. These findings suggest the potential application of this technique in cerebellar disorders.

BRAIN COMMUNICATIONS (2021)

Article Radiology, Nuclear Medicine & Medical Imaging

Diffusion dispersion imaging: Mapping oscillating gradient spin-echo frequency dependence in the human brain

Aidin Arbabi et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Diffusion-time dependence of diffusional kurtosis in the mouse brain

Manisha Aggarwal et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Radiology, Nuclear Medicine & Medical Imaging

Towards unconstrained compartment modeling in white matter using diffusion-relaxation MRI with tensor-valued diffusion encoding

Bjorn Lampinen et al.

MAGNETIC RESONANCE IN MEDICINE (2020)

Article Neurosciences

Correlation tensor magnetic resonance imaging

Rafael Neto Henriques et al.

NEUROIMAGE (2020)

Article Computer Science, Interdisciplinary Applications

Monte Carlo Simulations of Water Exchange Through Myelin Wraps: Implications for Diffusion MRI

Lorenza Brusini et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Maxwell-compensated design of asymmetric gradient waveforms for tensor-valued diffusion encoding

Filip Szczepankiewicz et al.

MAGNETIC RESONANCE IN MEDICINE (2019)

Review Biophysics

Quantifying brain microstructure with diffusion MRI: Theory and parameter estimation

Dmitry S. Novikov et al.

NMR IN BIOMEDICINE (2019)

Article Radiology, Nuclear Medicine & Medical Imaging

Fast, Na+/K+ pump driven, steady-state transcytolemmal water exchange in neuronal tissue: A study of rat brain cortical cultures

Ruiliang Bai et al.

MAGNETIC RESONANCE IN MEDICINE (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Intracellular water preexchange lifetime in neurons and astrocytes

Donghan M. Yang et al.

MAGNETIC RESONANCE IN MEDICINE (2018)

Article Pharmacology & Pharmacy

Size-Based Differentiation of Cancer and Normal Cells by a Particle Size Analyzer Assisted by a Cell-Recognition PC Software

Babita Shashni et al.

BIOLOGICAL & PHARMACEUTICAL BULLETIN (2018)

Article Chemistry, Physical

Cumulant expansions for measuring water exchange using diffusion MRI

Lipeng Ning et al.

JOURNAL OF CHEMICAL PHYSICS (2018)

Review Radiology, Nuclear Medicine & Medical Imaging

On modeling

Dmitry S. Novikov et al.

MAGNETIC RESONANCE IN MEDICINE (2018)

Article Radiology, Nuclear Medicine & Medical Imaging

Optimal Experimental Design for Filter Exchange Imaging: Apparent Exchange Rate Measurements in the Healthy Brain and in Intracranial Tumors

Bjorn Lampinen et al.

MAGNETIC RESONANCE IN MEDICINE (2017)

Review Clinical Neurology

Aquaporin Water Channels and Hydrocephalus

Alan S. Verkman et al.

PEDIATRIC NEUROSURGERY (2017)

Review Physics, Multidisciplinary

Time-Dependent Diffusion MRI in Cancer: Tissue Modeling and Applications

Olivier Reynaud

FRONTIERS IN PHYSICS (2017)

Article Radiology, Nuclear Medicine & Medical Imaging

PGSE, OGSE, and Sensitivity to Axon Diameter in Diffusion MRI: Insight from a Simulation Study

Ivana Drobnjak et al.

MAGNETIC RESONANCE IN MEDICINE (2016)

Article Neurosciences

Denoising of diffusion MRI using random matrix theory

Jelle Veraart et al.

NEUROIMAGE (2016)

Review Oncology

Red cell distribution width and cancer

Martina Montagnana et al.

ANNALS OF TRANSLATIONAL MEDICINE (2016)

Article Radiology, Nuclear Medicine & Medical Imaging

Apparent Exchange Rate Imaging in Anisotropic Systems

Casper K. S. Nderby et al.

MAGNETIC RESONANCE IN MEDICINE (2014)

Article Radiology, Nuclear Medicine & Medical Imaging

Oscillating Gradient Diffusion MRI Reveals Unique Microstructural Information in Normal and Hypoxia-Ischemia Injured Mouse Brains

Dan Wu et al.

MAGNETIC RESONANCE IN MEDICINE (2014)

Article Multidisciplinary Sciences

Revealing mesoscopic structural universality with diffusion

Dmitry S. Novikov et al.

PROCEEDINGS OF THE NATIONAL ACADEMY OF SCIENCES OF THE UNITED STATES OF AMERICA (2014)

Article Biochemical Research Methods

Gaussian phase distribution approximations for oscillating gradient spin echo diffusion MRI

Andrada Ianus et al.

JOURNAL OF MAGNETIC RESONANCE (2013)

Article Radiology, Nuclear Medicine & Medical Imaging

Noninvasive mapping of water diffusional exchange in the human brain using filter-exchange imaging

Markus Nilsson et al.

MAGNETIC RESONANCE IN MEDICINE (2013)

Review Radiology, Nuclear Medicine & Medical Imaging

The role of tissue microstructure and water exchange in biophysical modelling of diffusion in white matter

Markus Nilsson et al.

MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE (2013)

Review Clinical Neurology

Aquaporin 4 and neuromyelitis optica

Marios C. Papadopoulos et al.

LANCET NEUROLOGY (2012)

Article Endocrinology & Metabolism

Brain water mobility decreases after astrocytic aquaporin-4 inhibition using RNA interference

Jerome Badaut et al.

JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM (2011)

Article Computer Science, Interdisciplinary Applications

elastix: A Toolbox for Intensity-Based Medical Image Registration

Stefan Klein et al.

IEEE TRANSACTIONS ON MEDICAL IMAGING (2010)

Article Neurosciences

Orientationally invariant indices of axon diameter and density from diffusion MRI

Daniel C. Alexander et al.

NEUROIMAGE (2010)

Review Biophysics

Twenty-five Pitfalls in the Analysis of Diffusion MRI Data

Derek K. Jones et al.

NMR IN BIOMEDICINE (2010)

Article Biophysics

Monte Carlo study of a two-compartment exchange model of diffusion

Els Fieremans et al.

NMR IN BIOMEDICINE (2010)

Article Radiology, Nuclear Medicine & Medical Imaging

On the effects of a varied diffusion time in vivo: is the diffusion in white matter restricted?

Markus Nilsson et al.

MAGNETIC RESONANCE IMAGING (2009)

Article Radiology, Nuclear Medicine & Medical Imaging

Aldehyde Fixative Solutions Alter the Water Relaxation and Diffusion Properties of Nervous Tissue

Timothy M. Shepherd et al.

MAGNETIC RESONANCE IN MEDICINE (2009)

Review Genetics & Heredity

Aquaporins - new players in cancer biology

A. S. Verkman et al.

JOURNAL OF MOLECULAR MEDICINE-JMM (2008)

Article Chemistry, Physical

Suppression of background gradients in (B0 gradient-based) NMR diffusion experiments

Gang Zheng et al.

CONCEPTS IN MAGNETIC RESONANCE PART A (2007)

Article Radiology, Nuclear Medicine & Medical Imaging

Diffusion in compartmental systems. I. A comparison of an analytical model with simulations

C Meier et al.

MAGNETIC RESONANCE IN MEDICINE (2003)

Article Radiology, Nuclear Medicine & Medical Imaging

On the effects of gating in diffusion imaging of the brain using single shot EPI

S Skare et al.

MAGNETIC RESONANCE IMAGING (2001)

Article Radiology, Nuclear Medicine & Medical Imaging

Analysis of partial volume effects in diffusion-tensor MRI

AL Alexander et al.

MAGNETIC RESONANCE IN MEDICINE (2001)

Article Radiology, Nuclear Medicine & Medical Imaging

Simple linear formulation for magnetostimulation specific to MRI gradient coils

BA Chronik et al.

MAGNETIC RESONANCE IN MEDICINE (2001)