Strongback; Soft story mechanism; Damper arrangement; Stiffness irregularity; Experimental

向作者/读者索取更多资源

Structures susceptible to soft story mechanisms are particularly vulnerable to earthquakes. The strongback has been proposed as a way to prevent soft story mechanisms, but its impact on structural performance considering vertical stiffness irregularities and different arrangements of energy dissipation devices is unclear. This study investigates the effects of strongback on a small-scale four-story elastic structure with varying stiffness irregularities and damper arrangements. The results show that the strongback significantly reduces maximum story drift and makes the structural performance insensitive to damper position and distribution.
Structures susceptible to soft story mechanisms are particularly vulnerable to earthquakes because damage concentrated at a single story can lead to premature failure of the structure. The strongback, a stiff vertical spine pinned at the structure's base and running its height, has been proposed as a way to impose a more uniform pattern of floor displacements and prevent soft story mechanisms. However, changes in the impact of strongbacks on the performance of structures remain unclear when considering vertical stiffness irregularities at different positions along the height of a structure and different arrangements of energy dissipation devices in a structure. This study aims to address these gaps through an extensive parametric experimental investigation varying the location of vertical stiffness irregularities and the arrangement of dampers in a small-scale four-story elastic structure with and without a strongback. For this study, each configuration of the structure is loaded with shake table-produced seismic ground motion. The results of this study show that, regardless of which story a stiffness irregularity is located, the strongback significantly reduces the maximum story drift in the structure. Furthermore, with the strongback, the maximum story and roof drift are insensitive to damper position and distribution, whereas, without it, the damper position significantly impacts the structural performance. The strongback's ability to protect against soft story vertical irregularities, regardless of their locations, and the insensitivity of structural performance to damper arrangement when utilizing a strongback, presents promising new options for structural design, architectural design, and remediation efforts.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.5
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据