4.6 Article

Functional determination of emicizumab in presence of factor VIII activity

期刊

JOURNAL OF THROMBOSIS AND HAEMOSTASIS
卷 21, 期 12, 页码 3490-3500

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.jtha.2023.09.011

关键词

emicizumab; factor VIII; hemophilia A; neutralizing antibody; preanalytical phase

向作者/读者索取更多资源

This study evaluated the impact of plasma FVIII activity on determining emicizumab levels and proposed different strategies for correcting or preanalytical inhibition of FVIII. The results showed that inhibitor-based FVIII neutralization is a feasible strategy for accurately measuring plasma emicizumab levels in the presence of FVIII activity.
Background: Accurate measurement of emicizumab in the presence of factor (F) VIII is required in patients with severe hemophilia A treated with emicizumab, as well as additional need for FVIII substitution or emicizumab prophylaxis in patients with acquired or moderate to mild hemophilia A. However, the presence of FVIII potentially biases the results.Objectives: To assess the impact of plasma FVIII activity on determined emicizumab levels and evaluate different strategies for correction for or preanalytical inhibition of FVIII.Methods: Evaluated strategies comprised of the following: (1) calculation of actual emicizumab plasma levels based on measured FVIII activities and FVIII-affected emicizumab values, (2) preanalytical heat treatment (56 degrees C for 40 minutes), and (3) neutralization of FVIII activity using FVIII inhibitors. Emicizumab levels and FVIII activities were measured using a modified FVIII one-stage clotting assay and a chromogenic FVIII assay based on bovine factors, respectively.Results: Spiking experiments revealed a consistent linear association between FVIII activities and determined (FVIII-affected) emicizumab results at different emicizumab input levels (-0.12 mu g/mL per IU/dL of FVIII). This principally allowed for mathematical correction of measured emicizumab levels in the presence of FVIII. While a 40% to 50% activity loss of intrinsic plasma emicizumab through heat treatment was observed in patient samples, emicizumab spiked into FVIII-deficient plasma was not or only marginally affected. Application of inhibitor-based FVIII neutralization led to good agreement of results when compared with direct quantification of emicizumab by liquid chromatography-tandem mass spectrometry. Conclusion: Inhibitor-based FVIII neutralization appears to be a feasible strategy for accurate measurement of plasma emicizumab levels in the presence of FVIII activity.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据