4.3 Article

Law of diffusion bubbles produced by high-voltage pulsed electric field in liquid

期刊

ACTA PHYSICA SINICA
卷 72, 期 21, 页码 -

出版社

CHINESE PHYSICAL SOC
DOI: 10.7498/aps.72.20230443

关键词

pulsed electric field; diffusion bubble; ablation parameter; electrolysis reaction; risk of embolism

向作者/读者索取更多资源

This study investigated the effects of pulse parameters on diffusion bubbles during pulsed electric field ablation. The experimental results showed that the area of diffusion bubbles generated in the liquid is positively correlated with pulse voltage and input energy. Higher conductivity and longer pulse width can enhance the thermal effect and increase the area of diffusion bubbles. The electrolytic reaction may be the main source of diffusion bubbles when the needle electrode is the cathode. This study is expected to optimize the parameters for pulsed electric field ablation.
Pulsed electric field is a novel physical energy source for treating atrial fibrillation and tumor ablation, which has advantages over traditional thermal ablation, such as being non-thermal, short treatment time, tissue selectivity, and low contact pressure requirements. The diffusion bubbles generated during physical ablation may lead to gas embolism and silent cerebral events, with potential hazards such as tissue damage and cerebral ischemia. Previous studies have shown that the number of bubbles generated is correlated with the electrical properties of the treated object, pulse parameters (pulse waveform, treatment time and input energy), and electrodes. The number of bubbles are more significant at the cathode than at the anode, and the number of bubbles positively correlates with the input energy. However, to the best of our knowledge, no studies have been conducted to investigate the effects of ablation pulse parameters on diffusion bubbles. Therefore, in our experiment, a platform for producing pulses and observing diffusion bubble is built, and the needle-ring electrode we made realizes the capture and measurement of diffusion bubbles. Since pulses with a voltage of 3 kV and a pulse width of 100 its are commonly used as ablation parameters for atrial fibrillation and tumor in pulsed field ablation (PFA), the pulse width of unipolar pulse is selected as 5, 10, 50, and 100 its, and the number of pulses applied is 1. The pulse voltage is determined according to the parameters commonly used in PFA and the simulation calculation of the field strength distribution of the needle-ring electrode. After determining the parameters, this experiment explicitly investigates the relationships among diffusion bubbles and solution conductivity, pulse voltage, pulse width, input energy, and other parameters. Meanwhile, the size distributions of diffusion bubbles under different operating conditions are statistically investigated. Besides, the possible causes of diffuse bubbles are also explored. We evaluate the number of bubbles by measuring the crosssectional area of the diffusion bubbles from a top-down perspective. The experimental results show that the area of diffusion bubbles generated in the liquid is positively correlated with pulse voltage and input energy; high conductivity and long pulse width can enhance the thermal effect and increase the area of diffusion bubbles; diffusion bubbles with a diameter larger than 100 itm are easily generated under high conductivity and high pulse width conditions. By speculating on the results, the electrolytic reaction may be the main source of diffusion bubbles when the needle electrode is the cathode. This study is expected to optimize future pulsed electric field ablation parameters.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.3
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据