4.4 Article

Compensation of concomitant field effects in double diffusion encoding by means of added oscillating gradients

期刊

MAGNETIC RESONANCE IMAGING
卷 105, 期 -, 页码 133-141

出版社

ELSEVIER SCIENCE INC
DOI: 10.1016/j.mri.2023.11.006

关键词

Concomitant fields; Double diffusion encoding; Sequence design; Oscillating gradients; Optimization; Diffusion weighting

向作者/读者索取更多资源

This study presents a method for reducing concomitant field effects in double diffusion encoding (DDE) sequences by adding oscillating gradient pulses. The modified sequences successfully reduced accumulated concomitant phase without significant changes in the original sequence characteristics. The proposed method led to an increase in signal-to-noise ratio (SNR) for phantom and in vivo experiments, supported by simulations.
Maxwell or concomitant fields imprint additional phases on the transverse magnetization. This concomitant phase may cause severe image artifacts like signal voids or distort the quantitative parameters due to the induced intravoxel dephasing. In particular, double diffusion encoding (DDE) schemes with two pairs of bipolar diffusion-weighting gradients separated by a refocusing radiofrequency (RF) pulse are prone to concomitant field-induced artifacts. In this work, a method for reducing concomitant field effects in these DDE sequences based on addi-tional oscillating gradients is presented. These oscillating gradient pulses obtained by constrained optimization were added to the original gradient waveforms. The modified sequences reduced the accumulated concomitant phase without significant changes in the original sequence characteristics. The proposed method was applied to a DDE acquisition scheme consisting of 60 pairs of diffusion wave vectors. For phantom as well as for in vivo experiments, a considerable increase in the signal-to-noise ratio (SNR) was obtained. For phantom measurements with a diffusion weighting of b = 2000 s/mm2 for each of the gradient pairs, an SNR increase of up to 40% was observed for a transversal slice that had a distance of 5 cm from the isocenter. For equivalent slice parameters, in vivo measurements in the brain of a healthy volunteer exhibited an increase in SNR of up to 35% for b = 750 s/ mm2 for each weighting. These findings are supported by corresponding simulations, which also predict a positive effect on the SNR. In summary, the presented method leads to an SNR gain without additional RF refocusing pulses.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据