4.7 Article

Quantifying metallic components in aerosol filter samples using micro-synchrotron radiation X-ray fluorescence: With quartz filter as an example

期刊

ATMOSPHERIC ENVIRONMENT
卷 318, 期 -, 页码 -

出版社

PERGAMON-ELSEVIER SCIENCE LTD
DOI: 10.1016/j.atmosenv.2023.120205

关键词

Micro-synchrotron radiation; Metallic components; Personal exposure; X-ray fluorescence; QFFs

向作者/读者索取更多资源

This study developed a sensitive method to measure the metallic components of atmospheric fine particulate matter (PM2.5) and compared the results with different analysis methods. The concentrations of metallic components in personal PM2.5 samples were found to be significantly different from corresponding fixed-site samples. Personal sampling can reduce exposure misclassifications, and measuring metallic components is useful for exploring health risks and identifying sources of PM2.5.
Metals in atmospheric fine particulate matter (PM2.5) are presumed to have toxic effects. For environmental epidemiological studies, measuring the metallic components of PM2.5 collected by personal samplers and quartz fiber filters (QFF) has two key advantages: reducing exposure misclassification and enabling analyses of multiple (organic and inorganic) components on a single filter. We developed a sensitive, low-sample-consumption method to quantify the metallic components of PM2.5 collected on QFFs using micro-synchrotron radiation Xray fluorescence (mu-SRXRF). Teflon filter is used here as a reference to test the substrate applicability of QFF. This method requires only a 5-mm-diameter portion of a QFF and can simultaneously quantify 15 metals with atomic numbers Z = 19-34 (i.e., K-Se, excluding Sc). The analysis time for each sample was 120-360 s, and the method detection limits were 0.04-36.6 ng/m3. We validated this method by performing cross-comparisons with two external methods: offline inductively coupled plasma mass spectrometry (ICP-MS) and online X-ray fluorescence (XRF). The slopes of the linear fits between the mu-SRXRF and offline ICP-MS methods varied from 0.40 to 1, with R2 values ranging from 0.62 to 0.98. The slopes of the linear fits between the mu-SRXRF and online XRF methods were between 0.29 and 0.89, with R2 values ranging from 0.39 to 0.80. We applied the proposed method to analyze 391 personal PM2.5 samples collected in an epidemiological study conducted in urban Beijing. By comparing the results with the ambient concentrations from a fixed monitoring site, we found that the con-centrations of some metallic components in personal PM2.5 samples were significantly different from those in the corresponding fixed-site samples, with up to an order of magnitude difference. Because personal sampling can reduce the potential for exposure misclassifications, the high-resolution temporal analysis of metallic compo-nents in personal samples using the mu-SRXRF method could be a useful approach for exploring the health risks and identifying the sources of metallic components of PM2.5.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据