Lead-containing radiation-attenuating sterile gloves in simulated use: Lead transfer to sweat as an unknown risk to users

期刊

RADIOGRAPHY
卷 30, 期 1, 页码 159-162

出版社

ELSEVIER SCI LTD
DOI: 10.1016/j.radi.2023.10.013

关键词

-

向作者/读者索取更多资源

This study found that lead-containing gloves may present a risk of metal leaching when in contact with sweat, and the level of lead leaching depends on the acidity of the sweat and the duration of contact. Gloves with a protective lining reduce the transfer of lead into sweat, but significant levels of lead are still present.
Background: Lead protective gloves are widely used to attenuate scattered radiations during fluoroscopic-guided medical procedures, thereby reducing hand exposure to radiation.Aims: To determine whether lead-containing gloves present a risk of metal leaching onto the operator's skin, particularly due to the presence of sweat.Methods: Artificial sweat of varying acidity was introduced into two types of commercial gloves containing lead. The level of lead in the sweat was then assessed after different exposure times. Electron microscopy was used to observe the morphology of the glove layers. Results: Lead was detected in artificial sweat during each contact test on two different types of gloves. The concentration of lead increased with the acidity of the sweat, and the contact time. Gloves with a protective lining transferred less lead into sweat, but it was still present at significant levels. (i.e. few milligrams of lead per glove after one hour contact).Conclusions: Fluoroscopy operators should be aware of the risk of leaching of lead ions when using lead gloves under intensive conditions, although the potential harmfulness of lead ions leached into the glove remains essentially unknown.(c) 2023 The College of Radiographers. Published by Elsevier Ltd. All rights reserved.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

3.8
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据