4.4 Review

Optimizing coronary artery opacification and 3D reconstruction from human cadaver hearts in anatomy research

期刊

CURRENT PROBLEMS IN CARDIOLOGY
卷 49, 期 2, 页码 -

出版社

MOSBY-ELSEVIER
DOI: 10.1016/j.cpcardiol.2023.102216

关键词

Contrast agent injection; Coronary artery opacification; Human cadaver hearts; 3D reconstruction; Radiopaque product; Anatomical imaging

向作者/读者索取更多资源

This study aims to find the optimal dilution rate of a radiopaque product for CT imaging in order to accurately reconstruct the normal anatomy of coronary arteries.
Objective: This study seeks to identify the ideal dilution rate of a radiopaque product to optimize the visualization of coronary arteries and their branches within human cadaver hearts. The process involves obtaining images in the anatomy laboratory and subsequently constructing a three-dimensional model.Materials and methods: We utilized 30 human hearts fixed in 10 % formalin (9 females and 21 males) with a mean age of 79 +/- 5 years. The initial experiment, involving the first four hearts (referred to as group 1), encountered difficulties in opacifying coronary arteries. In this phase, a probabilistic injection of 20 % Visipaque and 80 % latex, with coronary sinus ostium closure, was performed. The optimal mixture ratio was then determined as 33 % Visipaque and 66 % latex. Recognizing the need for on-site injection at the CT Scan table, this protocol was applied to the subsequent 11 hearts in group 2. Closure of the coronary sinus was deemed unnecessary. The final 15 hearts, constituting group 3, revealed that the injection should be gradual, maintaining controlled pressure between 120 and 150 mm Hg. Post-injection, hearts were scanned with the injected coronary arteries using an Optima 660 CT scanner. Two-dimensional images were acquired with parameters set at 64 x 0.625 mm, 100 kV, 300-400 mA, and a rotation of 0.5 s. Subsequently, 3D reconstruction was conducted using Advantage Workstation 4.7 (GE Healthcare) and volume rendering with Volume Viewer software, version 15.Results: Significant differences in the percentage of opacified coronaries were observed among the three groups (p < 0.005). This variation underscores the learning curve and comprehension required before establishing a reliable method. Group 1 (N = 4) demonstrated minimal opacification, group 2 (N = 11) displayed partial opacification, while group 3 (N = 15) achieved 100 % opacification of coronary arteries.Conclusion: The successive experiments culminated in the development of a protocol for CT imaging, enabling accurate three-dimensional reconstruction of the normal anatomy of the main and secondary coronary arteries. Our work is grounded in a series of progressively refined and successful experiments.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据