4.7 Article

Impressive merger between green analytical approaches and quality- by-design for alcaftadine determination in eye drops and rabbit aqueous humor; application to stability study by two validated chromatographic methods

期刊

MICROCHEMICAL JOURNAL
卷 196, 期 -, 页码 -

出版社

ELSEVIER
DOI: 10.1016/j.microc.2023.109717

关键词

Alcaftadine; Analytical quality -by -design; Green analytical chemistry; Stability -indicating

向作者/读者索取更多资源

The main goal of this study was to develop two green chromatographic techniques, HPLC and TLC, for the determination of alcaftadine (ALF) in pharmaceutical formulation and biological samples. The developed HPLC technique showed high efficiency and minimal environmental impact, successfully identifying ALF in the presence of its degradate. The TLC method provided a stability indicating study for ALF and was determined to be safe, green, and eco-friendly.
Nowadays, the main target of many researchers is to develop green environmentally friendly techniques that could separate drugs without using hazardous solvents which may lead to a dreadful impact on the environment. Proceeding from this lofty goal, the main concern of this work is to develop two green chromatographic techniques, namely, HPLC and TLC to determine alcaftadine (ALF) in pharmaceutical formulation, rabbit aqueous humor, and in presence of its degradate. Fortunately, and for the first time in the history of ALF analysis, the developed HPLC technique in this work succeeded to determine ALF in the presence of its oxidative degradate via a fruitful integration between green analytical chemistry and analytical quality-by-design resulting in increasing efficiency and minimizing environmental impacts. Utilizing an XBridge (R) C18 (4.6 x 250 mm, 5 mu m) column, optimized chromatographic separation was accomplished utilizing isocratic elution with an ammonium acetate buffer (pH 5.0): ethanol (60:40, by volume) as the mobile phase, a flow rate of 1.5 mL/min, and UV detection at 282.0 nm. Over a concentration range of 0.1 to 8.0 mu g/mL, linearity was attained. Additionally, this work succeeded to determine ALF through a stability indicating study using thin layer chromatographic technique on TLC plates precoated with silica gel 60F-254 as a stationary phase using a developing system consisting of dichloromethane: ethanol: ammonia (5:5:0.1, by volume) and scanned at 282.0 nm with 0.5-20.0 mu g/band linearity range. Finally, the proposed methods were further assessed for their greenness profile using various greenness assessment tools. Fortunately, the developed methods proved to be safe, green, and eco-friendly.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据