4.5 Article

Summating Potential as Marker of Intracochlear Position in Bipolar Electrocochleography

相关参考文献

注意:仅列出部分参考文献,下载原文获取全部文献信息。
Article Otorhinolaryngology

Cochlear implantation in an animal model documents cochlear damage at the tip of the implant

Jose Santos Cruz de Andrade et al.

Summary: This experimental study investigated the electrophysiological changes during cochlear implant surgery in guinea pigs. The results showed that electrode insertion caused significant changes in the amplitude of extra-cochlear electrophysiological potentials, especially in deep insertions, while cochleostomy had a lesser impact. Preservation of electrical response to low frequency stimuli was observed in most cases.

BRAZILIAN JOURNAL OF OTORHINOLARYNGOLOGY (2022)

Article Audiology & Speech-Language Pathology

Band-Limited Chirp-Evoked Compound Action Potential in Guinea Pig: Comprehensive Neural Measure for Cochlear Implantation Monitoring

Youssef Adel et al.

Summary: This study investigates the use of chirps to enhance CAP monitoring sensitivity in a guinea pig model of cochlear implantation. The results show that chirps can efficiently synchronize neural firing in a limited frequency band and provide more robust CAP responses compared to equal-band clicks. The study suggests that chirps may be a more effective stimulus for neural measurements in cochlear implant patients with residual hearing.

EAR AND HEARING (2021)

Article Audiology & Speech-Language Pathology

Simultaneous Intra- and Extracochlear Electrocochleography During Electrode Insertion

Adrian Dalbert et al.

Summary: This study compared intracochlear and extracochlear ECochG signals during electrode insertion, finding that intracochlear recordings showed larger and more pronounced amplitude and phase changes not reflected in extracochlear recordings. There was a weak to moderate correlation between residual high-frequency hearing and ECochG signal amplitudes. Detecting cochlear trauma in the future may be possible through modeling expected changes in intracochlear ECochG during electrode insertions.

EAR AND HEARING (2021)

Article Audiology & Speech-Language Pathology

Relationship Between Electrocochleography, Angular Insertion Depth, and Cochlear Implant Speech Perception Outcomes

Michael W. Canfarotta et al.

Summary: Electrocochleography (ECochG) obtained before CI insertion provides important information for predicting speech perception outcomes in adults, with variables such as angular insertion depth (AID) and array design also playing significant roles. The combination of ECochG, AID, and array design accounts for approximately 72% of the variability in speech perception outcomes, suggesting that peripheral factors are crucial for speech perception with CIs.

EAR AND HEARING (2021)

Review Audiology & Speech-Language Pathology

The benefits of preserving residual hearing following cochlear implantation: a systematic review

Simone Schaefer et al.

Summary: The real-life benefits of hearing preservation cochlear implantation (HPCI) for children and adults primarily lie in improved speech perception in noise and music perception, with less significant improvements in speech perception in quiet and binaural cues. However, interpretation of the findings is hindered by small study groups and significant heterogeneity in various parameters.

INTERNATIONAL JOURNAL OF AUDIOLOGY (2021)

Article Neurosciences

Residual Hair Cell Responses in Electric-Acoustic Stimulation Cochlear Implant Users with Complete Loss of Acoustic Hearing After Implantation

Viral D. Tejani et al.

Summary: Changes in cochlear implant design and surgical techniques have enabled the preservation of residual acoustic hearing in many patients, but some may still experience complete loss of residual hearing. ECoG testing in patients with complete loss of residual hearing after surgery showed measurable CM responses despite no measurable acoustic hearing, suggesting a possible disconnect between hair cells and auditory nerve fibers. This disconnection may prevent proper encoding of auditory stimulation at higher auditory pathways.

JARO-JOURNAL OF THE ASSOCIATION FOR RESEARCH IN OTOLARYNGOLOGY (2021)

Review Otorhinolaryngology

Special electrodes for demanding cochlear conditions

Anandhan Dhanasingh et al.

Summary: The optimal matching of electrode array to cochlear anatomy is crucial for maximizing the benefits of CI technology, with MED-EL offering a variety of electrode array lengths and designs to accommodate different anatomical variations and needs of patients. Collaboration between MED-EL and CI surgeons worldwide has led to the successful implantation of various unique electrode designs in patients with special cochlear needs.

ACTA OTO-LARYNGOLOGICA (2021)

Article Audiology & Speech-Language Pathology

A cochlear scaling model for accurate anatomy evaluation and frequency allocation in cochlear implantation

Daniel Schurzig et al.

Summary: This study improved the precision of cochlear modeling by incorporating microscopic details of a large set of human cochleae and demonstrated the superior performance of the new model compared to previous ones. The new model is freely available for download and use, providing better prediction of cochlear microanatomy and 3D form in individual cases.

HEARING RESEARCH (2021)

Article Audiology & Speech-Language Pathology

Interaction Between Electric and Acoustic Stimulation Influences Speech Perception in Ipsilateral EAS Users

Marina Imsiecke et al.

EAR AND HEARING (2020)

Article Otorhinolaryngology

Preservation of residual hearing after cochlear implant surgery with slim modiolar electrode

Matti Iso-Mustajarvi et al.

EUROPEAN ARCHIVES OF OTO-RHINO-LARYNGOLOGY (2020)

Review Engineering, Biomedical

Recent advances in the implant-based drug delivery in otorhinolaryngology

Fei Tan et al.

ACTA BIOMATERIALIA (2020)

Article Multidisciplinary Sciences

Four-point impedance as a biomarker for bleeding during cochlear implantation

Christofer Bester et al.

SCIENTIFIC REPORTS (2020)

Article Otorhinolaryngology

Electric-acoustic stimulation with longer electrodes for potential deterioration in low-frequency hearing

Hidekane Yoshimura et al.

ACTA OTO-LARYNGOLOGICA (2020)

Review Physiology

Cochlear implants and other inner ear prostheses: today and tomorrow

Lina A. J. Reiss

CURRENT OPINION IN PHYSIOLOGY (2020)

Article Clinical Neurology

Individual Hearing Preservation Cochlear Implantation Using the Concept of Partial Insertion

Thomas Lenarz et al.

OTOLOGY & NEUROTOLOGY (2019)

Article Neurosciences

Hair cell and neural contributions to the cochlear summating potential

Andrew K. Pappa et al.

JOURNAL OF NEUROPHYSIOLOGY (2019)

Article Audiology & Speech-Language Pathology

Intracochlear Electrocochleography: Response Patterns During Cochlear Implantation and Hearing Preservation

Christopher K. Giardina et al.

EAR AND HEARING (2019)

Article Clinical Neurology

Multicenter US Clinical Trial With an Electric-Acoustic Stimulation (EAS) System in Adults: Final Outcomes

Harold C. Pillsbury et al.

OTOLOGY & NEUROTOLOGY (2018)

Review Otorhinolaryngology

Electrode Designs for Protection of the Delicate Cochlear Structures

Mark Downing

JOURNAL OF INTERNATIONAL ADVANCED OTOLOGY (2018)

Article Otorhinolaryngology

Cochlear Implant – State of the Art

Thomas Lenarz

LARYNGO-RHINO-OTOLOGIE (2017)

Article Medicine, Research & Experimental

Insertion Depth Impacts Speech Perception and Hearing Preservation for Lateral Wall Electrodes

Brendan P. O'Connell et al.

LARYNGOSCOPE (2017)

Article Clinical Neurology

Real-Time Intracochlear Electrocochleography Obtained Directly Through a Cochlear Implant

Michael S. Harris et al.

OTOLOGY & NEUROTOLOGY (2017)

Article Multidisciplinary Sciences

Spiral Form of the Human Cochlea Results from Spatial Constraints

M. Pietsch et al.

SCIENTIFIC REPORTS (2017)

Article Medicine, Research & Experimental

Round window electrocochleography before and after cochlear implant electrode insertion

Oliver F. Adunka et al.

LARYNGOSCOPE (2016)

Article Audiology & Speech-Language Pathology

The potential use of low-frequency tones to locate regions of outer hair cell loss

Aryn M. Kamerer et al.

HEARING RESEARCH (2016)

Article Audiology & Speech-Language Pathology

Extra- and Intracochlear Electrocochleography in Cochlear Implant Recipients

Adrian Dalbert et al.

AUDIOLOGY AND NEURO-OTOLOGY (2015)

Article Neurosciences

Distinguishing hair cell from neural potentials recorded at the round window

Mathieu Forgues et al.

JOURNAL OF NEUROPHYSIOLOGY (2014)

Article Otorhinolaryngology

Electrocochleography during Cochlear Implantation for Hearing Preservation

Marco Mandala et al.

OTOLARYNGOLOGY-HEAD AND NECK SURGERY (2012)

Review Audiology & Speech-Language Pathology

Electric-Acoustic Stimulation of the Auditory System: A Review of the First Decade

Christoph A. von Ilberg et al.

AUDIOLOGY AND NEURO-OTOLOGY (2011)

Review Audiology & Speech-Language Pathology

Electrocochleography: A Review of Recording Approaches, Clinical Applications, and New Findings in Adults and Children

John A. Ferraro

JOURNAL OF THE AMERICAN ACADEMY OF AUDIOLOGY (2010)

Article Clinical Neurology

Intracochlear Recordings of Electrophysiological Parameters Indicating Cochlear Damage

Oliver F. Adunka et al.

OTOLOGY & NEUROTOLOGY (2010)

Article Acoustics

Auditory steady-state responses to chirp stimuli based on cochlear traveling wave delay

Claus Elberling et al.

JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA (2007)

Article Audiology & Speech-Language Pathology

Representation of acoustic signals in the human cochlea in presence of a cochlear implant electrode

Jan Kiefer et al.

HEARING RESEARCH (2006)

Article Audiology & Speech-Language Pathology

Primary afferent and cochlear nucleus contributions to extracellular potentials during tone-bursts

P Sellick et al.

HEARING RESEARCH (2003)

Review Physiology

Mechanics of the mammalian cochlea

L Robles et al.

PHYSIOLOGICAL REVIEWS (2001)