4.4 Article

A Clinical Study to Assess Diffuse Reflectance Spectroscopy with an Auto-Calibrated, Pressure-Sensing Optical Probe in Head and Neck Cancer

期刊

CURRENT ONCOLOGY
卷 30, 期 3, 页码 2751-2760

出版社

MDPI
DOI: 10.3390/curroncol30030208

关键词

diffuse optical spectroscopy; head and neck squamous cell carcinoma; diffuse reflectance spectroscopy; optical biopsy; optical sensing

类别

向作者/读者索取更多资源

Diffuse reflectance spectroscopy (DRS) is a powerful tool for quantifying optical and physiological tissue properties. In this clinical study, a pressure-sensing and automatic self-calibration DRS was assessed and validated in patients with head and neck squamous cell carcinoma (HNSCC). The results showed that cancerous tissues have a significantly lower hemoglobin saturation compared to normal tissues, suggesting tumor hypoxia. The study also demonstrated the feasibility of conducting optical spectroscopy measurements on intact lesions prior to removal during HNSCC procedures.
Diffuse reflectance spectroscopy (DRS) is a powerful tool for quantifying optical and physiological tissue properties such as hemoglobin oxygen saturation and vascularity. DRS is increasingly used clinically for distinguishing cancerous lesions from normal tissue. However, its widespread clinical acceptance is still limited due to uncontrolled probe-tissue interface pressure that influences reproducibility and introduces operator-dependent results. In this clinical study, we assessed and validated a pressure-sensing and automatic self-calibration DRS in patients with suspected head and neck squamous cell carcinoma (HNSCC). The clinical study enrolled nineteen patients undergoing HNSCC surgical biopsy procedures. Patients consented to evaluation of this improved DRS system during surgery. For each patient, we obtained 10 repeated measurements on one tumor site and one distant normal location. Using a Monte Carlo-based model, we extracted the hemoglobin saturation data along with total hemoglobin content and scattering properties. A total of twelve cancer tissue samples from HNSCC patients and fourteen normal tissues were analyzed. A linear mixed effects model tested for significance between repeated measurements and compared tumor versus normal tissue. These results demonstrate that cancerous tissues have a significantly lower hemoglobin saturation compared to normal controls (p < 0.001), which may be reflective of tumor hypoxia. In addition, there were minimal changes over time upon probe placement and repeated measurement, indicating that the pressure-induced changes were minimal and repeated measurements did not differ significantly from the initial value. This study demonstrates the feasibility of conducting optical spectroscopy measurements on intact lesions prior to removal during HNSCC procedures, and established that this probe provides diagnostically-relevant physiologic information that may impact further treatment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.4
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据