4.6 Article

High-Precision Measurement of Brillouin Frequency Shift in Brillouin Optical Time-Domain Reflectometer Based on Half-Peak Fitting Algorithm of Power Spectrum

期刊

IEEE ACCESS
卷 11, 期 -, 页码 26843-26849

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2023.3258701

关键词

Fitting; Scattering; Temperature measurement; Strain; Power measurement; Time-frequency analysis; Time-domain analysis; Brillouin scattering; Brillouin frequency shift; double-peak fitting; least squares; optical fiber sensors

向作者/读者索取更多资源

In this study, a half-peak fitting algorithm is proposed to measure the Brillouin frequency shift(BFS) with high accuracy and stability. It can precisely determine the double-peak spectrum and detect the position in the transition section of a temperature change or strain event. The algorithm reduces calculation complexity, enhances measurement speed, and improves temperature measurement accuracy by about 1 fold with about 20% calculation of the full fitting.
The Brillouin optical time-domain reflectometer (BOTDR) system, which is based on the Brillouin frequency shift (BFS) of the scattering spectrum, has been widely applied to monitor the temperature and strain in many fields. The measurement accuracy of the BFS directly affects the monitoring and location of the temperature change or strain events. In this study, the characteristics of the least-squares fitting optimal solution of the Brillouin power spectrum are theoretically investigated, and a half-peak fitting algorithm is proposed to measure the BFS with high accuracy and stability. In particular, it can precisely determine the double-peak spectrum and detect the position in the transition section of a temperature change or strain event. Furthermore, it can reduce calculation complexity and enhance measurement speed by dropping most of the data. For the fiber under test (FUT) with a length of 12 km, 200 groups of time domain data were processed using a probe pulse of width 50 ns and sampling rate 1 GHz. The half-peak fitting algorithm increased the temperature measurement accuracy by similar to 1 fold, with similar to 20% calculation of full fitting. Meanwhile, it effectively eliminated the influence of minor peak in the double-peak spectrum, and optimized the spatial resolution of the temperature change position to 0.1 m, which is the maximum limitation by sampling rate.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据