Magnetite azolla impedimetric nanobiosensor for phthalic acid esters quantification

期刊

ANALYTICAL METHODS
卷 15, 期 16, 页码 1985-1997

出版社

ROYAL SOC CHEMISTRY
DOI: 10.1039/d3ay00030c

关键词

-

向作者/读者索取更多资源

Two sensitive and efficient impedimetric biosensors based on azolla fern dried powder (AZ) and magnetite-modified azolla nanocomposites (MAZ NCs) were introduced and their interactions with four phthalic acid esters (PAEs) were investigated. The results showed that these biosensors offer high sensitivity and performance for the determination of trace PAEs in aqueous samples.
Phthalic acid esters (PAEs) are a group of organic compounds that show vulnerability effects in different stages of human development. In this work, two sensitive and efficient impedimetric biosensors (IBs) were introduced and their interactions with four PAEs, namely dibutyl phthalate (DBP), dimethyl phthalate (DMP), di(2-ethylhexyl) phthalate (DEHP), and dicyclohexyl phthalate (DCHP), in aqueous solutions with these biosensors were separately investigated via electrochemical impedance spectroscopy (EIS). The surface of a copper electrode was modified by azolla fern dried powder (AZ) and magnetite-modified azolla nanocomposites (MAZ NCs) to form an azolla-based impedimetric biosensor (AZIB) and magnetite azolla nanocomposite-based impedimetric nanobiosensor (MAZIB), respectively. Determinations of PAEs with the designed biosensors were conducted based on their blocking effect on the biosensor surface to ferrous ions oxidation. After each impedimetric measurement, the electrode surface was covered again with the modifier. Nyquist plots were obtained and indicated that the charge-transfer resistance (R-CT) values of the bare electrode, AZIB, and MAZIB without injection of PAEs were 468.8, 438.7, and 285.1 k omega, respectively. After the separate injection of DBP, DMP, DEHP, and DCHP (3 mu g L-1) on the surface of AZIB and MAZIB, R-CT values were obtained as 563.9, 588.5, 548.7, and 570.1 k omega for AZIB and 878.2, 1219.2, 754.3, and 814.7 k omega for MAZIB, respectively. It was observed that the PAE blockers with a smaller structure provided better point-by-point coverage of the surface, which led to a bigger shift in R-CT. The linear relationship between the EIS responses and each PAE concentration was investigated in the range of 0.1-1000 mu g L-1. The limit of detection (LOD) and limit of quantification (LOQ) values were obtained in the ranges of 0.003-0.005 mu g L-1 and 0.010-0.016 mu g L-1 for AZIB and 0.008-0.009 mu g L-1 and 0.027-0.031 mu g L-1 for MAZIB, respectively. The results showed that these biosensors can be used to determine PAEs in real aqueous samples with good relative recoveries ranging from 93.0-97.7% (RSD < 2.58%) for AZIB and 93.3-99.3% (RSD < 2.45%) for MAZIB. The results confirmed that these impedimetric biosensors offer high sensitivity and performance for the determination of trace PAEs in aqueous samples.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据