4.7 Article

Can carotid artery Doppler variations induced by the end-expiratory occlusion maneuver predict fluid responsiveness in septic shock patients?

期刊

CRITICAL CARE
卷 27, 期 1, 页码 -

出版社

BMC
DOI: 10.1186/s13054-023-04422-9

关键词

Fluid responsiveness; End-expiratory occlusion test (EEOt); Fluid challenge; Carotid artery Doppler; Heart-lung interaction

向作者/读者索取更多资源

This study investigates the feasibility of using carotid Doppler (CD) to assess fluid responsiveness in patients with septic shock. The changes in CD peak velocity (CDPV) were found to be correlated with cardiac index (CI) changes and could predict fluid responsiveness. However, the changes in CDPV and corrected flow time (cFT) were not accurate predictors of fluid responsiveness.
BackgroundAn increase in cardiac index (CI) during an end-expiratory occlusion test (EEOt) predicts fluid responsiveness in ventilated patients. However, if CI monitoring is unavailable or the echocardiographic window is difficult, using the carotid Doppler (CD) could be a feasible alternative to track CI changes. This study investigates whether changes in CD peak velocity (CDPV) and corrected flow time (cFT) during an EEOt were correlated with CI changes and if CDPV and cFT changes predicted fluid responsiveness in patients with septic shock.MethodsProspective, single-center study in adults with hemodynamic instability. The CDPV and cFT on carotid artery Doppler and hemodynamic variables from the pulse contour analysis EV1000 (TM) were recorded at baseline, during a 20-s EEOt, and after fluid challenge (500 mL). We defined responders as those who increased CI >= 15% after a fluid challenge.ResultsWe performed 44 measurements in 18 mechanically ventilated patients with septic shock and without arrhythmias. The fluid responsiveness rate was 43.2%. The changes in CDPV were significantly correlated with changes in CI during EEOt (r = 0.51 [0.26-0.71]). A significant, albeit lower correlation, was found for cFT (r = 0.35 [0.1-0.58]). An increase in CI >= 5.35% during EEOt predicted fluid responsiveness with 78.9% sensitivity and 91.7% specificity, with an area under the ROC curve (AUROC) of 0.85. An increase in CDPV >= 10.5% during an EEOt predicted fluid responsiveness with 96.2% specificity and 53.0% sensitivity with an AUROC of 0.74. Sixty-one percent of CDPV measurements (from - 13.5 to 9.5 cm/s) fell within the gray zone. The cFT changes during EEOt did not accurately predict fluid responsiveness.ConclusionsIn septic shock patients without arrhythmias, an increase in CDPV greater than 10.5% during a 20-s EEOt predicted fluid responsiveness with > 95% specificity. Carotid Doppler combined with EEOt may help optimize preload when invasive hemodynamic monitoring is unavailable. However, the 61% gray zone is a major limitation (retrospectively registered on Clinicaltrials.gov NCT04470856 on July 14, 2020).

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.7
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据