4.6 Article

A Modified Length-Based Grading Method for Assessing Coronary Artery Calcium Severity on Non-Electrocardiogram-Gated Chest Computed Tomography: A Multiple-Observer Study

期刊

KOREAN JOURNAL OF RADIOLOGY
卷 24, 期 4, 页码 284-293

出版社

KOREAN SOCIETY OF RADIOLOGY
DOI: 10.3348/kjr.2022.0826

关键词

Calcium; Coronary vessels; Thorax; Tomography; X ray computed

向作者/读者索取更多资源

The study aimed to validate a simplified scoring method for assessing the severity of coronary artery calcium (CAC) on non-electrocardiogram (ECG)-gated chest computed tomography (CT). The modified length-based grading demonstrated better accuracy and consistency with cardiac CT results compared to visual assessment.
Objective: To validate a simplified ordinal scoring method, referred to as modified length-based grading, for assessing coronary artery calcium (CAC) severity on non-electrocardiogram (ECG)-gated chest computed tomography (CT). Materials and Methods: This retrospective study enrolled 120 patients (mean age +/- standard deviation [SD], 63.1 +/- 14.5 years; male, 64) who underwent both non-ECG-gated chest CT and ECG-gated cardiac CT between January 2011 and December 2021. Six radiologists independently assessed CAC severity on chest CT using two scoring methods (visual assessment and modified length-based grading) and categorized the results as none, mild, moderate, or severe. The CAC category on cardiac CT assessed using the Agatston score was used as the reference standard. Agreement among the six observers for CAC category classification was assessed using Fleiss kappa statistics. Agreement between CAC categories on chest CT obtained using either method and the Agatston score categories on cardiac CT was assessed using Cohen's kappa. The time taken to evaluate CAC grading was compared between the observers and two grading methods. Results: For differentiation of the four CAC categories, interobserver agreement was moderate for visual assessment (Fleiss kappa, 0.553 [95% confidence interval {CI}: 0.496-0.610]) and good for modified length-based grading (Fleiss kappa, 0.695 [95% CI: 0.636-0.754]). The modified length-based grading demonstrated better agreement with the reference standard categorization with cardiac CT than visual assessment (Cohen's kappa, 0.565 [95% CI: 0.511-0.619 for visual assessment vs. 0.695 [95% CI: 0.638-0.752] for modified length-based grading). The overall time for evaluating CAC grading was slightly shorter in visual assessment (mean +/- SD, 41.8 +/- 38.9 s) than in modified length-based grading (43.5 +/- 33.2 s) (P < 0.001). Conclusion: The modified length-based grading worked well for evaluating CAC on non-ECG-gated chest CT with better interobserver agreement and agreement with cardiac CT than visual assessment.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据