4.6 Article

Real-Time Identification of Malignant Biliary Strictures on Cholangioscopy Images Using Explainable Convolutional Neural Networks With Heatmaps

期刊

IEEE ACCESS
卷 11, 期 -, 页码 49943-49956

出版社

IEEE-INST ELECTRICAL ELECTRONICS ENGINEERS INC
DOI: 10.1109/ACCESS.2023.3276642

关键词

Deep learning; indeterminate biliary strictures; real-time image classification; explainable deep learning

向作者/读者索取更多资源

The determination of benign or malignant bile duct strictures is challenging, and current methods still lack consistency in diagnosis. Biopsy is commonly used for accurate diagnosis, but sampling errors can lead to false-negative results. In this study, a convolutional neural network is proposed for real-time classification of malignant biliary strictures. The model shows good performance in still images with sensitivity of 0.8577 and F1-score of 0.8395, and even better performance with video inference with sensitivity of 0.9024 and F1-score of 0.9193. The model can also achieve real-time inference at a speed of 83 frames per second.
Determination of benign or malignant etiology of bile duct strictures is difficult. Currently, a digital single-operator cholangioscopy allows endoscopists to examine the bile duct with greater accuracy. Consequently, lesions in the bile duct can be detected directly with their own eyes. However, there is still inconsistency of diagnosis among endoscopists. Therefore, a biopsy is usually considered as a gold standard. Thus, pieces of tissue are taken from the bile duct and undergo examination. A false negative of cancer diagnosis from a sampling error of biopsy leads to the need to repeat procedures. In this work, we propose a convolutional neural network specifically designed for classifying malignant biliary strictures in real-time. In our development, this model can generate output not only for classification but also for a class activation map, which relies solely on an image-level label rather than annotation position. The model mainly focuses on tissues, not on equipment e.g. guide wire. To increase the number of cholangioscopy images, and solve the issue of equipment, a guide-wire augmentation is invented. To employ a video inference, our model for still images is further modified. In our experiment, all models are run on 3 patient-based bootstraps. The data contains 104 patients' records collected at King Chulalongkorn Memorial Hospital with 885 images: 447 malignant and 438 benign images. The model's performance for still images is 0.8577 and 0.8395 in terms of sensitivity and F1, respectively. With our video inference algorithm, the sensitivity of the model attains 0.9024 and the F1-score achieves 0.9193. Finally, the model can facilitate real-time inference with a speed of 83 frames per second.

作者

我是这篇论文的作者
点击您的名字以认领此论文并将其添加到您的个人资料中。

评论

主要评分

4.6
评分不足

次要评分

新颖性
-
重要性
-
科学严谨性
-
评价这篇论文

推荐

暂无数据
暂无数据